CoChat

Oxygen Permeability and Water Content of Silicone Hydrogel Contact Lens Materials

EFRON, NATHAN, MORGAN, PHILIP B., CAMERON, IAN D., BRENNAN, NOEL A., GOODWIN, MARIE · 2007 · Optometry and Vision Science
Cited by 139

The DOI matches its Crossref record.

Abstract

PURPOSE: To measure the oxygen permeability (Dk) and water content (WC) of silicone hydrogel (Si-Hy) contact lens materials. METHODS: Randomized and masked determinations of the Dk of 5 Si-Hy and two hydrogel materials were made using a modified version of the polarographic measurement method described in ISO 9913-1. Stacks of one to six parallel-sided contact lenses (all -1.00 DS) were evaluated, with each stack measured at least twice. The resulting value for t/Dk was plotted against the thickness (t) of each stack, with Dk calculated as the inverse of the gradient of this relationship. This methodology corrects for boundary effects. A mathematical calculation was used to correct for edge effects. Gravimetric determination of lens WC was conducted at room temperature and 35 degrees C. RESULTS: Measured values (+/-95% CI) of Dk, and WC at room temperature, with manufacturer-claimed values in parentheses, were Focus Night and Day: Dk 162.0 +/- 9.8 (140), WC 23.0 +/- 3.2 (24); Acuvue Oasys: Dk 107.4 +/- 7.4 (103), WC 36.9 +/- 1.0 (38); O2 Optix: Dk 80.5 +/- 4.9 (110), WC 32.1 +/- 1.2 (33); PureVision: Dk 75.9 +/- 6.6 (91), WC 35.8 +/- 1.3 (36); Acuvue Advance: Dk 75.2 +/- 9.8 (60), WC 46.5 +/- 1.1 (47); 1. Day Acuvue: Dk 21.0 +/- 1.0 (21.4), WC [not measured] (58); and Seequence: Dk 8.2 +/- 0.7 (8.5), WC 36.6 +/- 2.7 (38). CONCLUSIONS: Claimed Dk values for Acuvue Oasys and the two reference hydrogel materials fell within the 95% confidence interval of our measured values. Our measurements of Dk for the other four Si-Hy lenses were not in agreement with claimed values. There is a general inverse relation between Dk and WC (both at 35 degrees C) for Si-Hy lenses. Our modified polarographic methodology can be successfully employed for measuring the Dk of Si-Hy materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/opx.0b013e31804375ed

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 139

Metadata

Authors
EFRON, N., MORGAN, P. B., CAMERON, I. D., BRENNAN, N. A., & GOODWIN, M.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2007-04
Volume
84
Issue
4
Pages
E328-E337
ISSN
1040-5488 (ISSN-L)
OpenAlex
W1559467950
Cited by
139
References
0
FWCI
5.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen Permeability and Water Content of Silicone Hydrogel Contact Lens Materials. https://app.cochat.ai/papers/10.1097/opx.0b013e31804375ed
The paper
EFRON, N., MORGAN, P. B., CAMERON, I. D., BRENNAN, N. A., & GOODWIN, M. (2007). Oxygen Permeability and Water Content of Silicone Hydrogel Contact Lens Materials. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e31804375ed

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.