Oxygen Permeability and Water Content of Silicone Hydrogel Contact Lens Materials
The DOI matches its Crossref record.
Abstract
PURPOSE: To measure the oxygen permeability (Dk) and water content (WC) of silicone hydrogel (Si-Hy) contact lens materials. METHODS: Randomized and masked determinations of the Dk of 5 Si-Hy and two hydrogel materials were made using a modified version of the polarographic measurement method described in ISO 9913-1. Stacks of one to six parallel-sided contact lenses (all -1.00 DS) were evaluated, with each stack measured at least twice. The resulting value for t/Dk was plotted against the thickness (t) of each stack, with Dk calculated as the inverse of the gradient of this relationship. This methodology corrects for boundary effects. A mathematical calculation was used to correct for edge effects. Gravimetric determination of lens WC was conducted at room temperature and 35 degrees C. RESULTS: Measured values (+/-95% CI) of Dk, and WC at room temperature, with manufacturer-claimed values in parentheses, were Focus Night and Day: Dk 162.0 +/- 9.8 (140), WC 23.0 +/- 3.2 (24); Acuvue Oasys: Dk 107.4 +/- 7.4 (103), WC 36.9 +/- 1.0 (38); O2 Optix: Dk 80.5 +/- 4.9 (110), WC 32.1 +/- 1.2 (33); PureVision: Dk 75.9 +/- 6.6 (91), WC 35.8 +/- 1.3 (36); Acuvue Advance: Dk 75.2 +/- 9.8 (60), WC 46.5 +/- 1.1 (47); 1. Day Acuvue: Dk 21.0 +/- 1.0 (21.4), WC [not measured] (58); and Seequence: Dk 8.2 +/- 0.7 (8.5), WC 36.6 +/- 2.7 (38). CONCLUSIONS: Claimed Dk values for Acuvue Oasys and the two reference hydrogel materials fell within the 95% confidence interval of our measured values. Our measurements of Dk for the other four Si-Hy lenses were not in agreement with claimed values. There is a general inverse relation between Dk and WC (both at 35 degrees C) for Si-Hy lenses. Our modified polarographic methodology can be successfully employed for measuring the Dk of Si-Hy materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical applications of hydrogels: A review of patents and commercial products
Caló, E., & Khutoryanskiy, V. V. (2015) · European Polymer Journal · doi:10.1016/j.eurpolymj.2014.11.024 · Cited by 2,634
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
Peng, C.-C., Kim, J., & Chauhan, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.113 · Cited by 263
Global contact lens prescribing 2000-2020
Morgan, P. B., & Efron, N. (2022) · Clinical and Experimental Optometry · doi:10.1080/08164622.2022.2033604 · Cited by 102
Self-citationNguyen, D. C. T., Dowling, J., Ryan, R., McLoughlin, P., & Fitzhenry, L. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.101487 · Cited by 61
Metadata
- Authors
- EFRON, N., MORGAN, P. B., CAMERON, I. D., BRENNAN, N. A., & GOODWIN, M.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2007-04
- Volume
- 84
- Issue
- 4
- Pages
- E328-E337
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W1559467950
- Cited by
- 139
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen Permeability and Water Content of Silicone Hydrogel Contact Lens Materials. https://app.cochat.ai/papers/10.1097/opx.0b013e31804375ed
- The paper
- EFRON, N., MORGAN, P. B., CAMERON, I. D., BRENNAN, N. A., & GOODWIN, M. (2007). Oxygen Permeability and Water Content of Silicone Hydrogel Contact Lens Materials. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e31804375ed
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.