The DOI matches its Crossref record.
Peripheral Refraction in Myopic Patients After Orthokeratology
Open accessAbstract
PURPOSE: The purpose of this study was to characterize the central and peripheral refraction across the horizontal meridian of the visual field before and after myopic corneal refractive therapy (CRT) with contact lenses. METHODS: Twenty-eight right eyes from 28 subjects (mean age +/- SD = 24.6 +/- 6.3 years) were fitted with Paragon CRT contact lenses to treat myopia between -0.88 and -5.25 D of spherical equivalent. Along with a complete set of examination procedures to assess suitability for treatment, the central and peripheral refractions were measured along the horizontal meridian up to 35 degrees of eccentricity in the nasal and temporal retinal area in 5 degrees steps. RESULTS: Baseline central average spherical equivalent (M) measured by subjective refraction changed from -1.95 +/- 1.27 D to -0.38 +/- 0.67 D. Changes in M component ranged between 1.42 +/- 0.89 D at center and 0.43 +/- 0.88 D at 20 degrees in the temporal retina (p < 0.002). At 25 degrees to both sides of the central refraction measurement, peripheral refraction after treatment was not statistically different from baseline values (p > 0.351). Beyond the 25 degrees limit, M component changed in the myopic direction up to -1.11 +/- 0.88 D at 35 degrees in temporal retina (p < 0.001). Treatment induced was symmetric between nasal and temporal visual field along the horizontal meridian (p > 0.05 for all eccentricities). Furthermore, the degree of myopic increase in spherical equivalent for 30 degrees (r2 = 0.573, p < 0.001) and 35 degrees (r2 = 0.645, p < 0.001) eccentric refraction was highly correlated with axial spherical equivalent at baseline. CONCLUSIONS: CRT inverts the pattern of peripheral refraction in spherical equivalent refraction, creating a treatment area of myopic reduction within the central 25 degrees of visual field, and a myopic shift beyond the 25 degrees. In peripheral refraction for 30 degrees and 35 degrees, the amount of myopia induced in terms of spherical equivalent has an almost 1:1 relationship with the amount of baseline spherical equivalent refraction to be corrected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Myopia Control with Orthokeratology Contact Lenses in Spain: Refractive and Biometric Changes
Santodomingo-Rubido, J., Villa-Collar, C., Gilmartin, B., & Gutiérrez-Ortega, R. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8005 · Cited by 334
Self-citationVisual performance with lenses correcting peripheral refractive errors
Atchison, D. A., Mathur, A., & Varnas, S. R. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000033 · Cited by 29
Metadata
- Authors
- Queirós, A., González-Méijome, J. M., Jorge, J., Villa-Collar, C., & Gutiérrez, A. R.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2010-05
- Volume
- 87
- Issue
- 5
- Pages
- 323-329
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2044313006
- Cited by
- 200
- References
- 0
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peripheral Refraction in Myopic Patients After Orthokeratology. https://app.cochat.ai/papers/10.1097/opx.0b013e3181d951f7
- The paper
- Queirós, A., González-Méijome, J. M., Jorge, J., Villa-Collar, C., & Gutiérrez, A. R. (2010). Peripheral Refraction in Myopic Patients After Orthokeratology. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e3181d951f7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.