Spectacle Lenses Designed to Reduce Progression of Myopia: 12-Month Results
Open accessAbstract
Purpose. To report the results of 12‐month wear of three novel spectacle lens designs intended to reduce peripheral hyperopic defocus and one standard design control lens and their effect on the progression of myopia in Chinese children aged 6 to 16 years. Methods. Chinese children (n = 210) with myopia (−0.75 D to −3.50 D sphere, cylinder ≤−1.50 D) were randomized to one of four groups wearing either one of three novel spectacle lens designs (types I, II, or III) or conventional, single‐vision spectacle lenses. Data were collected at 6 and 12 months. Primary and secondary outcome measures were the changes in central cycloplegic auto‐refraction and eye axial length, respectively. Peripheral refraction along the horizontal meridian (nasal and temporal) was taken at baseline with and without spectacle lenses. Multivariate linear regression was used to adjust analyses for important covariates. Results. Progression in eyes wearing control spectacle lenses at 6 and 12 months was −0.55 D ± 0.35 D and −0.78 ± 0.50 D, respectively. For the entire group, no statistically significant differences were observed in the rates of progression with the novel designs in comparison to control spectacle lenses. However, in younger children (6 to 12 years) with parental history of myopia (n = 100), there was significantly less progression (−0.68 D ± 0.47 D vs. −0.97 D ± 0.48 D) with lens type III compared with control spectacles (mean difference, 0.29 D, std error, 0.11, p = 0.038). Conclusions. There were no statistically significant differences in the rate of progression of myopia between the control and novel lens wearing eyes for the age group 6 to 16 years. The finding of reduced progression of myopia with type III lens design in younger children with parental myopia needs to be validated in a more targeted study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Homeostasis of Eye Growth and the Question of Myopia
Wallman, J., & Winawer, J. (2004) · Neuron · doi:10.1016/j.neuron.2004.08.008 · Cited by 1,060
Atropine for the Treatment of Childhood Myopia
Chua, W.-H., Balakrishnan, V., Chan, Y.-H., Tong, L., Ling, Y., Quah, B.-L., & Tan, D. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.062 · Cited by 695
Mutti, D. O., Hayes, J. R., Mitchell, G. L., Jones, L. A., Moeschberger, M. L., Cotter, S. A., Kleinstein, R. N., Manny, R. E., Twelker, J. D., & Zadnik, K. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0562 · Cited by 634
High Myopia and Glaucoma Susceptibility
Xu, L., Wang, Y., Wang, S., Wang, Y., & Jonas, J. B. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.06.050 · Cited by 596
Gwiazda, J., Hyman, L., Hussein, M., Everett, D., Norton, T. T., Kurtz, D., Leske, M. C., Manny, R., Marsh-Tootle, W., & Scheiman, M. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0816 · Cited by 595
Peripheral Vision Can Influence Eye Growth and Refractive Development in Infant Monkeys
Smith, E. L., Kee, C.-S., Ramamirtham, R., Qiao-Grider, Y., & Hung, L.-F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0445 · Cited by 523
Self-citationEffects of Foveal Ablation on Emmetropization and Form-Deprivation Myopia
Smith, E. L., Ramamirtham, R., Qiao-Grider, Y., Hung, L.-F., Huang, J., Kee, C.-S., Coats, D., & Paysse, E. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-1264 · Cited by 308
Self-citationGwiazda, J. E., Hyman, L., Norton, T. T., Hussein, M. E. M., Marsh-Tootle, W., Manny, R., Wang, Y., & Everett, D. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-1306 · Cited by 297
Peripheral refraction along the horizontal and vertical visual fields in myopia
Atchison, D. A., Pritchard, N., & Schmid, K. L. (2006) · Vision Research · doi:10.1016/j.visres.2005.10.023 · Cited by 285
Siatkowski, R. M., Cotter, S. A., Crockett, R. S., Miller, J. M., Novack, G. D., & Zadnik, K. (2008) · Journal of American Association for Pediatric Ophthalmology and Strabismus · doi:10.1016/j.jaapos.2007.10.014 · Cited by 183
Progression of Myopia in Hong Kong Chinese Schoolchildren Is Slowed by Wearing Progressive Lenses
Leung, J., & Brown, B. H. (1999) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1999.tb05413.x · Cited by 179
Hasebe, S., Ohtsuki, H., Nonaka, T., Nakatsuka, C., Miyata, M., Hamasaki, I., & Kimura, S. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-0385 · Cited by 156
Stone, R. A., & Flitcroft, I. (2004) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v33n1p7 · Cited by 150
Congdon, N. G., Wang, Y., Song, Y., Choi, K. C., Zhang, M., Zhou, Z., Xie, Z., Li, L., Liu, X., Sharma, A., et al. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1160 · Cited by 141
The effectiveness of progressive addition lenses on the progression of myopia in Chinese children
Yang, Z., Lan, W., Ge, J., Liu, W., Chen, X., Chen, L., & Yu, M. (2008) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2008.00608.x · Cited by 117
Self-citationLens Thickness Changes among Schoolchildren in Taiwan
Shih, Y., Chiang, T., & Lin, L. L.-K. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-3090 · Cited by 108
Cited by
Morgan, I. G., Ohno-Matsui, K., & Saw, S.-M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60272-4 · Cited by 1,871
The complex interactions of retinal, optical and environmental factors in myopia aetiology
Flitcroft, D. I. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.06.004 · Cited by 903
Baird, P. N., Saw, S.-M., Lanca, C., Guggenheim, J. A., Smith III, E. L., Zhou, X., Matsui, K.-O., Wu, P.-C., Sankaridurg, P., Chia, A., et al. (2020) · Nature Reviews Disease Primers · doi:10.1038/s41572-020-00231-4 · Cited by 838
Self-citationEfficacy Comparison of 16 Interventions for Myopia Control in Children
Huang, J., Wen, D., Wang, Q., McAlinden, C., Flitcroft, I., Chen, H., Saw, S. M., Chen, H., Bao, F., Zhao, Y., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2015.11.010 · Cited by 752
Hiraoka, T., Kakita, T., Okamoto, F., Takahashi, H., & Oshika, T. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8453 · Cited by 488
Metadata
- Authors
- Sankaridurg, P., Donovan, L., Varnas, S., Ho, A., Chen, X., Martinez, A., Fisher, S., Lin, Z., Smith, E. L., Ge, J., & Holden, B.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2010-09
- Volume
- 87
- Issue
- 9
- Pages
- 631-641
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2077157584
- Cited by
- 299
- References
- 16
- FWCI
- 13.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.