Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record.

Peripheral Refraction in Myopic Children Wearing Orthokeratology and Gas-Permeable Lenses

Kang, Pauline, Swarbrick, Helen·2011·Optometry and Vision Science

Abstract

PURPOSE: To investigate changes in peripheral refraction after orthokeratology (OK) and rigid gas-permeable (GP) lens wear in progressing myopic children and to compare these peripheral defocus changes with reported changes in adults wearing OK. METHODS: Sixteen myopic children subjects were fitted with an OK lens in one eye for overnight wear and a GP lens in the other eye for daily wear. Central and peripheral refraction were measured at baseline and then after 3 mo of lens wear. RESULTS: At baseline, myopic children showed relative peripheral hyperopia compared with central refraction at and beyond 20° in the temporal visual field (VF) and 30° in the nasal VF. Three months of OK lens wear produced hyperopic shifts in refraction between 30° in the temporal VF and 20° in the nasal VF. Peripheral refraction was similar to center at all positions in the temporal VF while remaining significantly myopic at all locations in the nasal VF. No change in either central or peripheral refraction was found after 3 mo in the eye assigned for GP lens wear. CONCLUSIONS: OK significantly reduced myopia in the central 20° VF in myopic children, converting relative peripheral hyperopia measured at baseline to relative peripheral myopia. These changes in children are similar to changes reported in myopic adults wearing OK lenses. No change in either central or peripheral refraction was found after 3 mo of daily GP lens wear. OK lenses can be used to induce myopic defocus in the periphery in myopic children and may thus provide a potential mechanism for myopia control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/opx.0b013e31820f16fb

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Kang, P., & Swarbrick, H.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2011-04
Volume
88
Issue
4
Pages
476-482
ISSN
1040-5488 (ISSN-L)
OpenAlex
W2040009590
Cited by
236
References
0
FWCI
9.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Peripheral Refraction in Myopic Children Wearing Orthokeratology and Gas-Permeable Lenses. https://app.cochat.ai/papers/10.1097/opx.0b013e31820f16fb
The paper
Kang, P., & Swarbrick, H. (2011). Peripheral Refraction in Myopic Children Wearing Orthokeratology and Gas-Permeable Lenses. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e31820f16fb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.