Grating Acuity and Contrast Tests for Clinical Trials of Severe Vision Loss
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the reliability and validity of grating visual acuity (VA) and contrast sensitivity (CS) tests, which could be useful outcome measures to assess changes in severely reduced vision. METHODS: The Grating Acuity Test (GAT) and Grating Contrast Sensitivity (GCS) tests, which involve the detection of grating orientation in a four-Alternative Forced Choice paradigm on a liquid crystal display screen, were compared with the well-validated Early Treatment of Diabetic Retinopathy Study (ETDRS) and Pelli-Robson (PR) charts. Grating tests were repeated two or three times within-visit, across three or four sessions, in 20 legally blind subjects: 8 with retinitis pigmentosa (RP) (16 eyes) and 12 with other retinal diseases (OR) (16 eyes). RESULTS: VA determined by ETDRS and GAT was in good agreement and scaled very similarly, as shown by regression of the within-session difference between the two measures against their mean [RP group: slope (m) = 0.11; 95% confidence interval [CI]: -0.06, 0.29; p = 0.21; OR group: m = -0.07; 95% CI: 0.33, 0.20; p = 0.62]. On average, higher logCS levels were obtained using the GCS than the PR in both groups. The two CS measures scaled similarly in the RP group (m = 0.07; 95% CI: -0.09, 0.22; p = 0.39) but not in the OR group (m = 0.41; 95% CI: 0.12, 0.70; p = 0.005). The within- and between-visit 95% coefficient of repeatability (CR.95) were 0.11 to 0.17 log units for the ETDRS charts and GAT in both groups and 0.14 to 0.15 log units for the PR and GCS in the RP group, whereas the OR group demonstrated more variability in CS. Between-visit CR.95 did not significantly change with mean VA or CS for the ETDRS, PR, or GCS tests, but RP patients' CR.95 on the GAT increased significantly with decreasing VA. Floor effects occurred for some RP eyes with ETDRS and PR charts but not with the GAT and GCS. CONCLUSIONS: Computer-driven grating tests appear to be reliable, capable of evaluating vision that may fall outside of the range of standard clinical tests and may be useful during clinical trials for advanced eye disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Bahrami, H., Melia, M., & Dagnelie, G. (2006) · BMC Ophthalmology · doi:10.1186/1471-2415-6-23 · Cited by 88
Self-citation
Cited by
Advances in retinal prosthesis systems
Bloch, E., Luo, Y., & da Cruz, L. (2019) · Therapeutic Advances in Ophthalmology · doi:10.1177/2515841418817501 · Cited by 201
Orientation and mobility assessment in retinal prosthetic clinical trials
Geruschat, D. R., Bittner, A. K., & Dagnelie, G. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182686251 · Cited by 31
“CS thresholds were measured using four-alternative forced choice orientation discrimination of computer-generated square wave gratings projected onto a screen.(2) Gratings were presented at a size twice as large as each subject’s grating VA resolution limit.”
MethodSelf-citationMacDonald, I. M., Moen, C., Duncan, J. L., Tsang, S. H., Cehajic-Kapetanovic, J., & Aleman, T. S. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.3.17 · Cited by 20
Metadata
- Authors
- Bittner, A. K., Jeter, P., & Dagnelie, G.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2011-10
- Volume
- 88
- Issue
- 10
- Pages
- 1153-1163
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2088384494
- Cited by
- 36
- References
- 2
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grating Acuity and Contrast Tests for Clinical Trials of Severe Vision Loss. https://app.cochat.ai/papers/10.1097/opx.0b013e3182271638
- The paper
- Bittner, A. K., Jeter, P., & Dagnelie, G. (2011). Grating Acuity and Contrast Tests for Clinical Trials of Severe Vision Loss. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e3182271638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.