Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the intraexaminer repeatability and intersession reproducibility of corneal deformation measurement using Scheimpflug noncontact tonometry (Corvis ST) on normal subjects. METHODS: Thirty-seven adults aged 20 to 48 years were invited to have their corneal deformation and curvature measurements taken using Corvis ST and Pentacam, respectively. Three consecutive measurements were taken for each instrument between 9:00 and 11:00 AM for intraexaminer repeatability analysis. Participants returned between 3:00 and 5:00 PM the same day for intersession reproducibility analysis. RESULTS: The most repeatable corneal parameter measured by Corvis ST was central corneal thickness ([CCT] ICC, 0.96; precision, 10.85 μm; repeatability, 15.34 μm; CV, 1.01%), followed by deformation amplitude ([DA] ICC, 0.80; precision, 0.08 mm; repeatability, 0.13 mm; CV, 4.33%), first applanation time ([1st A-time] ICC, 0.77; precision, 0.22 milliseconds; repeatability, 0.31 milliseconds; CV, 1.42), and intraocular pressure ([IOP] ICC, 0.75; precision, 1.39 mm Hg; repeatability, 1.97 mm Hg; CV, 4.98). Other parameters showed poor repeatability. The DA and 1st A-time showed good intersession reproducibility. The 95% limits of agreement were +0.13 to -0.13 mm for DA and +0.27 to -0.33 milliseconds for 1st A-time. The DA was negatively correlated with central corneal thickness (r = -0.53, p < 0.001) but not with corneal curvatures (flattest curvature, r = 0.13, p = 0.46; steepest curvature, r = 0.05, p = 0.75). CONCLUSIONS: Corneal deformation parameters DA and 1st A-time were repeatable and reproducible. A thinner cornea was associated with a higher corneal deformation. Measurement of DA serves as an indicator of corneal biomechanical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311 · cited 1×
“To investigate the biomechanical properties of human cornea in vivo, a noncontact tonometer (NCT) called the Ocular Response Analyser ([ORA] Reichert Ophthalmic Instruments, Buffalo, NY) was introduced in 2005.(7) However, outputs of ORA do not give direct description about the mechanical behavior of cornea.”
MethodStatistics notes: Measurement error
Bland, J. M., & Altman, D. G. (1996) · BMJ · doi:10.1136/bmj.312.7047.1654 · Cited by 835
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753 · cited 3×
“It is also reported that the effect of corneal thickness or curvature only explains part of the variance of intraocular pressure (IOP), whereas other aspects of the cornea may contribute, thus the biomechanical properties of the cornea is noted.(5,6) To investigate the biomechanical properties of human cornea in vivo,…”
BackgroundCentral Corneal Thickness and Corneal Hysteresis Associated With Glaucoma Damage
Congdon, N. G., Broman, A. T., Bandeen-Roche, K., Grover, D., & Quigley, H. A. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.12.007 · Cited by 507
McAlinden, C., Khadka, J., & Pesudovs, K. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00851.x · Cited by 436 · cited 1×
“‘‘Reproducibility’’ refers to the variability in repeated measures when factors are varied.(14) The purpose of this study was to evaluate the intraexaminer repeatability and intersession reproducibility of Corvis ST measurements on normal subjects.”
BackgroundThe Repeatability of Corneal Thickness Measures
Marsich, M. M., & Bullimore, M. A. (2000) · Cornea · doi:10.1097/00003226-200011000-00007 · Cited by 291
Diurnal variations in human corneal thickness.
Harper, C., Boulton, M., BENNETT, D. B., Marcyniuk, B., Jarvis-Evans, J., Tullo, A. B., & Ridgway, A. E. A. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.12.1068 · Cited by 259 · cited 1×
“It is well supported that diurnal variation exists for corneal thickness.(23,24) Increased corneal thickness (both central and peripheral) is shown immediately after waking because of overnight corneal swelling of approximately 2.”
BackgroundA comparison of four methods of tonometry: method agreement and interobserver variability
Tonnu, P.-A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.056614 · Cited by 225
Cited by
Corneal biomechanics – a review
Kling, S., & Hafezi, F. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12345 · Cited by 194
Metadata
- Authors
- Hon, Y., & Lam, A. K. C.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2013-01
- Volume
- 90
- Issue
- 1
- Pages
- e1-e8
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2089431536
- Cited by
- 235
- References
- 22
- FWCI
- 14.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.