The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electromyography-Controlled Exoskeletal Upper-Limb–Powered Orthosis for Exercise Training After Stroke
Abstract
OBJECTIVE: Robot-assisted exercise shows promise as a means of providing exercise therapy for weakness that results from stroke or other neurological conditions. Exoskeletal or "wearable" robots can, in principle, provide therapeutic exercise and/or function as powered orthoses to help compensate for chronic weakness. We describe a novel electromyography (EMG)-controlled exoskeletal robotic brace for the elbow (the active joint brace) and the results of a pilot study conducted using this brace for exercise training in individuals with chronic hemiparesis after stroke. DESIGN: Eight stroke survivors with severe chronic hemiparesis were enrolled in this pilot study. One subject withdrew from the study because of scheduling conflicts. A second subject was unable to participate in the training protocol because of insufficient surface EMG activity to control the active joint brace. The six remaining subjects each underwent 18 hrs of exercise training using the device for a period of 6 wks. Outcome measures included the upper-extremity component of the Fugl-Meyer scale and the modified Ashworth scale of muscle hypertonicity. RESULTS: Analysis revealed that the mean upper-extremity component of the Fugl-Meyer scale increased from 15.5 (SD 3.88) to 19 (SD 3.95) (P = 0.04) at the conclusion of training for the six subjects who completed training. Combined (summated) modified Ashworth scale for the elbow flexors and extensors improved from 4.67 (+/-1.2 SD) to 2.33 (+/-0.653 SD) (P = 0.009) and improved for the entire upper limb as well. All subjects tolerated the device, and no complications occurred. CONCLUSION: EMG-controlled powered elbow orthoses can be successfully controlled by severely impaired hemiparetic stroke survivors. This technique shows promise as a new modality for assisted exercise training after stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nudo, R. J., Wise, B. M., SiFuentes, F., & Milliken, G. W. (1996) · Science · doi:10.1126/science.272.5269.1791 · Cited by 1,911
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582
Timmermans, A. A., Seelen, H. A., Willmann, R. D., & Kingma, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-1 · Cited by 483
Basteris, A., Nijenhuis, S. M., Stienen, A. H., Buurke, J. H., Prange, G. B., & Amirabdollahian, F. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-111 · Cited by 408
Metadata
- Authors
- Stein, J., Narendran, K., McBean, J., Krebs, K., & Hughes, R.
- Venue
- American Journal of Physical Medicine & Rehabilitation
- Published
- 2007-04
- Volume
- 86
- Issue
- 4
- Pages
- 255-261
- ISSN
- 0894-9115 (ISSN-L)
- OpenAlex
- W2056759886
- Cited by
- 170
- References
- 2
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electromyography-Controlled Exoskeletal Upper-Limb–Powered Orthosis for Exercise Training After Stroke. https://app.cochat.ai/papers/10.1097/phm.0b013e3180383cc5
- The paper
- Stein, J., Narendran, K., McBean, J., Krebs, K., & Hughes, R. (2007). Electromyography-Controlled Exoskeletal Upper-Limb–Powered Orthosis for Exercise Training After Stroke. American Journal of Physical Medicine & Rehabilitation. https://doi.org/10.1097/phm.0b013e3180383cc5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.