Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Facial Nerve Grading Instruments: Systematic Review of the Literature and Suggestion for Uniformity

Fattah, Adel Y., Gurusinghe, Anthony D. R., Gavilan, Javier, Hadlock, Tessa A., Marcus, Jeff R., Marres, Henri, Nduka, Charles C., Slattery, William H., Snyder-Warwick, Alison K. · 2015 · Plastic and Reconstructive Surgery

Abstract

BACKGROUND: A variety of facial nerve grading scales have been developed over the years with the intended goals of objectively documenting facial nerve function,tracking recovery, and facilitating communication between practitioners. Numerous scales have been proposed; however, all are subject to limitation because of varying degrees of subjectivity, reliability, or longitudinal applicability. At present, such scales remain the only widely accessible modalities for facial functional assessment. The authors' objective was to ascertain which scales(s) best accomplish the goals of objective assessment. METHODS: A systematic review of the English language literature was performed to identify facial nerve grading instruments. Each system was evaluated against the following criteria: convenience of clinical use, regional scoring, static and dynamic measures, features secondary to facial palsy (e.g., synkinesis), reproducibility with low interobserver and intraobserver variability, and sensitivity to changes over time and/or following interventions. RESULTS: From 666 articles, 19 facial nerve grading scales were identified. Only the Sunnybrook Facial Grading Scale satisfied all criteria. The Facial Nerve Grading Scale 2.0 (or revised House-Brackmann Scale) fulfilled all criteria except intraobserver reliability, which has not been assessed. CONCLUSIONS: Facial nerve grading scales intend to provide objectivity and uniformity of reporting to otherwise subjective analysis. The Facial Nerve Grading Scale 2.0 requires further evaluation for intraobserver reliability. The Sunnybrook Facial Grading Scale has been robustly evaluated with respect to the criteria prescribed in this article. Although sophisticated technology-based methodologies are being developed for potential clinical application,the authors recommend widespread adoption of the Sunnybrook Facial Grading Scale as the current standard in reporting outcomes of facial nerve disorders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/prs.0000000000000905

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 271

Metadata

Authors
Fattah, A. Y., Gurusinghe, A. D. R., Gavilan, J., Hadlock, T. A., Marcus, J. R., Marres, H., Nduka, C. C., Slattery, W. H., & Snyder-Warwick, A. K.
Venue
Plastic and Reconstructive Surgery
Published
2015-02
Volume
135
Issue
2
Pages
569-579
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2048225593
Cited by
271
References
22
FWCI
6.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Facial Nerve Grading Instruments: Systematic Review of the Literature and Suggestion for Uniformity. https://app.cochat.ai/papers/10.1097/prs.0000000000000905
The paper
Fattah, A. Y., Gurusinghe, A. D. R., Gavilan, J., Hadlock, T. A., Marcus, J. R., Marres, H., Nduka, C. C., Slattery, W. H., & Snyder-Warwick, A. K. (2015). Facial Nerve Grading Instruments: Systematic Review of the Literature and Suggestion for Uniformity. Plastic and Reconstructive Surgery. https://doi.org/10.1097/prs.0000000000000905

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.