The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The Foreign Body Response: At the Interface of Surgery and Bioengineering
Abstract
BACKGROUND: The surgical implantation of materials and devices has dramatically increased over the past decade. This trend is expected to continue with the broadening application of biomaterials and rapid expansion of aging populations. One major factor that limits the potential of implantable materials and devices is the foreign body response, an immunologic reaction characterized by chronic inflammation, foreign body giant cell formation, and fibrotic capsule formation. METHODS: The English literature on the foreign body response to implanted materials and devices is reviewed. RESULTS: Fibrotic encapsulation can cause device malfunction and dramatically limit the function of an implanted medical device or material. Basic science studies suggest a role for immune and inflammatory pathways at the implant-host interface that drive the foreign body response. Current strategies that aim to modulate the host response and improve construct biocompatibility appear promising. CONCLUSIONS: This review article summarizes recent basic science, preclinical, and clinicopathologic studies examining the mechanisms driving the foreign body response, with particular focus on breast implants and synthetic meshes. Understanding these molecular and cellular mechanisms will be critical for achieving the full potential of implanted biomaterials to restore human tissues and organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The role of macrophage phenotype in vascularization of tissue engineering scaffolds
Spiller, K. L., Anfang, R. R., Spiller, K. J., Ng, J., Nakazawa, K. R., Daulton, J. W., & Vunjak-Novakovic, G. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.02.012 · Cited by 948
Kyriakides, T. R., Foster, M. J., Keeney, G. E., Tsai, A., Giachelli, C. M., Clark-Lewis, I., Rollins, B. J., & Bornstein, P. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63265-8 · Cited by 226
Biomaterial topography alters healing in vivo and monocyte/macrophage activation in vitro
Bota, P. C. S., Collie, A. M. B., Puolakkainen, P., Vernon, R. B., Sage, E. H., Ratner, B. D., & Stayton, P. S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32893 · Cited by 186
Matrix metalloproteinases and their inhibitors in the foreign body reaction on biomaterials
Jones, J. A., McNally, A. K., Chang, D. T., Qin, L. A., Meyerson, H., Colton, E., Kwon, I. L. K., Matsuda, T., & Anderson, J. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31220 · Cited by 121
Essential Role of DAP12 Signaling in Macrophage Programming into a Fusion-Competent State
Helming, L., Tomasello, E., Kyriakides, T. R., Martinez, F. O., Takai, T., Gordon, S., & Vivier, E. (2008) · Science Signaling · doi:10.1126/scisignal.1159665 · Cited by 116
Cited by
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
“Implantable biomaterials are predominantly hydrophobic and have high affinity to a several proteins [24,152].”
BackgroundExamination of the foreign body response to biomaterials by nonlinear intravital microscopy
Dondossola, E., Holzapfel, B. M., Alexander, S., Filippini, S., Hutmacher, D. W., & Friedl, P. (2016) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0007 · Cited by 215
Inflammation in tissue engineering: The Janus between engraftment and rejection
Crupi, A., Costa, A., Tarnok, A., Melzer, S., & Teodori, L. (2015) · European Journal of Immunology · doi:10.1002/eji.201545818 · Cited by 108
Fibroblasts: Diverse Cells Critical to Biomaterials Integration
Hannan, R. T., Peirce, S. M., & Barker, T. H. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00244 · Cited by 59
In Vivo Evaluation of the Biocompatibility of Biomaterial Device
Frazão, L. P., Vieira de Castro, J., & Neves, N. M. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-981-15-3262-7_8 · Cited by 23
Metadata
- Authors
- Major, M. R., Wong, V. W., Nelson, E. R., Longaker, M. T., & Gurtner, G. C.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2015-05
- Volume
- 135
- Issue
- 5
- Pages
- 1489-1498
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2331734391
- Cited by
- 181
- References
- 5
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Foreign Body Response: At the Interface of Surgery and Bioengineering. https://app.cochat.ai/papers/10.1097/prs.0000000000001193
- The paper
- Major, M. R., Wong, V. W., Nelson, E. R., Longaker, M. T., & Gurtner, G. C. (2015). The Foreign Body Response: At the Interface of Surgery and Bioengineering. Plastic and Reconstructive Surgery. https://doi.org/10.1097/prs.0000000000001193
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.