CoChat

Effect of Omega-3 Fatty Acids on Heart Rate Variability in Depressed Patients With Coronary Heart Disease

Open access
Carney, Robert M., Freedland, Kenneth E., Stein, Phyllis K., Steinmeyer, Brian C., Harris, William S., Rubin, Eugene H., Krone, Ronald J., Rich, Michael W. · 2010 · Psychosomatic Medicine
Cited by 42

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Objective: To determine whether omega-3 fatty acid (FA) increases the natural log of very low frequency (lnVLF) power, an index of heart rate variability (HRV), and reduces 24-hour heart rate (HR) in depressed patients with coronary heart disease (CHD). Low intake of omega-3 FAs is associated with depression and with low HRV, and all three are associated with an increased risk of death in patients with CHD. Methods: Thirty-six depressed patients with CHD randomized to receive 50 mg of sertraline and 2 g of omega-3/day, and 36 randomized to sertraline and a placebo, had 24-hour HRV measured at baseline and after 10 weeks of treatment. Results: There was a significant treatment × time interaction for covariate adjusted lnVLF (p = .009), for mean 24-hour HR (p = .03), and for 1-minute resting HR (p = .02). The interaction was not significant for three other measures of HRV. LnVLF did not change over time in the omega-3 arm but decreased in the placebo arm (p = .002), suggesting that omega-3 may have prevented or slowed deterioration in cardiac autonomic function. Conclusions: The effects of omega-3 FAs on lnVLF and HR, although modest, were detected after only 10 weeks of treatment with 2 g per day of omega-3. Whether a longer course of treatment or a higher dose of omega-3 would further decrease HR, improve other indices of HRV, or reduce mortality in depressed CHD patients should be investigated. CHD = coronary heart disease; FAs = fatty acids; EPA = eicosapentaenoic acid; DHA = docosahexaenoic acid; HRV = heart rate variability; VLF = very low frequency; BDI-II = Beck Depression Inventory; RBC = red blood cell; HR = heart rate; ULF = ultra low frequency; ECG = electrocardiogram; bpm = beats per minute; MI = myocardial infarction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/psy.0b013e3181eff148

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Metadata

Authors
Carney, R. M., Freedland, K. E., Stein, P. K., Steinmeyer, B. C., Harris, W. S., Rubin, E. H., Krone, R. J., & Rich, M. W.
Venue
Psychosomatic Medicine
Published
2010-10
Volume
72
Issue
8
Pages
748-754
ISSN
0033-3174 (ISSN-L)
OpenAlex
W2026094982
Cited by
42
References
10
FWCI
2.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.