CoChat

Evaluation of Nurse Interaction With Bar Code Medication Administration Technology in the Work Environment

The DOI matches its Crossref record; 37 of the 39 references it cites were found in a registry or an index.

Abstract

Objectives: This study explores nurses' use of bar code medication administration (BCMA) technology from a human factors viewpoint. The BCMA technology consists of a medication network server and handheld devices that connect to medication administration record data through wireless radiofrequency link. Methods: A total of 62 observations of medication administration were conducted in 1 academic hospital. Observations were performed by a team of 2 people (a human factors engineer and a pharmacist) in a variety of critical care and medical/surgical units. Data were recorded on the medication administration task, the BCMA technology, organizational factors (in particular interruptions), the physical environment, and various individual factors related to the nurses and patients. Results: Eighteen different sequences were identified and represented very large variability in the order in which steps of the medication administration process are performed; some of the sequences can be considered as potentially unsafe acts. We identified various working conditions that can hinder the medication administration process. For example, 20 instances of interruptions were observed. Some patient factors (e.g., isolation patients) were also identified that made the BCMA-based medication administration process challenging. Conclusions: When introducing a new technology into the health care environment, it is important to assess changes in workflow and tasks that may result from the use of the technology. Our study shows the use of direct observation in helping to identify the work system factors that facilitate or hinder the medication administration tasks. This information can help health care organizations identify opportunities to redesign the process and/or the technology to maximize worker efficiency, interaction with the technology, and patient safety.

Overview

Integrity signals

Registry

Crossref · 10.1097/pts.0b013e3180319de7

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

4 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 37 references

Cited by

See all 124

Metadata

Authors
Carayon, P., Wetterneck, T. B., Hundt, A. S., Ozkaynak, M., DeSilvey, J., Ludwig, B., Ram, P., & Rough, S. S.
Affiliations
  • University of Wisconsin–Madison (US)
  • University of Washington Medical Center (US)
Corresponding author
  • Carayon, Pascale
  • Ozkaynak, Mustafa
Venue
Journal of Patient Safety
Published
2007-03
Volume
3
Issue
1
Pages
34-42
ISSN
1549-8417 (ISSN-L)
OpenAlex
W2045134397
Cited by
117
References
39
Citations by year
2026: 2 · 2025: 3 · 2024: 1 · 2023: 3 · 2022: 5 · 2021: 6 · 2020: 4 · 2019: 4 · 2018: 4 · 2017: 8 · 2016: 5 · 2015: 8 · 2014: 5 · 2013: 16 · 2012: 11
FWCI
8.92
Type
journal article
Language
en
Open access
closed
Locations
Journal of Patient Safety (publishedVersion)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
barcode medication administration, nurses, human factors, interruptions, patient isolation, patient safety, technology implementation, work system redesign, critical care nursing, medication administration records

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Nurse Interaction With Bar Code Medication Administration Technology in the Work Environment. https://app.cochat.ai/papers/10.1097/pts.0b013e3180319de7
The paper
Carayon, P., Wetterneck, T. B., Hundt, A. S., Ozkaynak, M., DeSilvey, J., Ludwig, B., Ram, P., & Rough, S. S. (2007). Evaluation of Nurse Interaction With Bar Code Medication Administration Technology in the Work Environment. Journal of Patient Safety. https://doi.org/10.1097/pts.0b013e3180319de7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.