Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Development and Evaluation of the Institute for Healthcare Improvement Global Trigger Tool

Classen, David C., Lloyd, Robert C., Provost, Lloyd, Griffin, Frances A., Resar, Roger · 2008 · Journal of Patient Safety

Abstract

Objectives: To develop and evaluate a more robust approach for the detection of adverse events in hospital patients using an enhanced Institute for Healthcare Improvement Global Trigger Tool methodology. Methods: We refined the Institute for Healthcare Improvement Global Trigger methodology using a 2-stage review approach with initial review by 4 clinicians followed by a second review by 2 physicians and then a consensus process. We used a 2-step process for evaluation, and all 6 reviewers participated in both training and, then, testing phase. We measured agreement between all reviewers for the presence and severity of adverse events during the training and testing phase using percent agreement and kappa. Results: This study used 15 training records containing 22 adverse events and 50 testing records containing 49 adverse events. Initially, the 6 reviewer's agreement with the training records ranged from 38.5% to 76.9%, with kappa ranges from −0.077 to 0.512. After training, percent agreement with the testing records ranged from 66.7% to 93.9%, with kappa values ranging from 0.164 to 0.703. All levels of improvement in reviewer agreement were statistically significant, at the 0.05 level or better, except one of the nonphysician reviewers, whose improvement (71.7% to 83.5%) was significant at only the 0.06 level. Conclusions: We have developed a robust trigger methodology for detection of adverse events in hospital patients using a retrospective record review approach with a 2-stage review process. This approach has shown the capability, when used with trained reviewers, to achieve high levels of agreement on the presence and severity of adverse events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/pts.0b013e318183a475

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
Classen, D. C., Lloyd, R. C., Provost, L., Griffin, F. A., & Resar, R.
Venue
Journal of Patient Safety
Published
2008-09
Volume
4
Issue
3
Pages
169-177
ISSN
1549-8417 (ISSN-L)
OpenAlex
W2066039932
Cited by
180
References
1
FWCI
8.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and Evaluation of the Institute for Healthcare Improvement Global Trigger Tool. https://app.cochat.ai/papers/10.1097/pts.0b013e318183a475
The paper
Classen, D. C., Lloyd, R. C., Provost, L., Griffin, F. A., & Resar, R. (2008). Development and Evaluation of the Institute for Healthcare Improvement Global Trigger Tool. Journal of Patient Safety. https://doi.org/10.1097/pts.0b013e318183a475

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.