The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Safety, Efficiency, and Cost Conflicts in Emergency Department Point of Care Troponin Testing
Abstract
Background and Objectives: Assessment of acute coronary syndrome (ACS) has pressured rapid diagnostic evaluation through point of care troponins (POCT-Tns). However, POCT-Tns have demonstrated inconsistent accuracy compared to laboratory (LABT)-Tn. A POCT-Tn used inappropriately to “rule-out” ACS can lead to premature diagnostic closure. We aimed to minimize indiscriminate POCT-Tn testing, while balancing test turnaround time (TAT), institutional cost, and impact on patient time to disposition (TTD). Methods: A quality improvement (QI) initiative from 2018 to 2022 included educational interventions and electronic health record (EHR) adaptations. We evaluated test characteristics, trended test frequency, TATs, cost, and TTD. We used statistical process control charts to evaluate changes in test frequency over time. We used the Mann-Whitney U and Wilcoxon Signed-Rank Sum test to analyze changes in TAT, TTD, and cost. Results: POCT-Tn had high discordance with LAB-Tn (9.7%) and low sensitivity (52.5%). SPCs showed a significant decrease in POCT-Tn tests performed over time. LABT-Tn TATs were longer than POCT-Tn (54 vs 21 min; P < .001). Total Tn testing costs decreased by $668 827.83 annually. Compared to pre-initiative, arrival to disposition was 20 min longer for patients receiving a LABT-Tn ( P < .001) and 37 min shorter for patients receiving a POCT with reflex to LABT-Tn ( P < .001). Conclusion: POCT-Tn test characteristics may place patients at risk for missed ACS. A combined approach using education and EHR adaptations decreased use of indiscriminate POCT-Tn tests, decreased health care costs, and resulted in clinically appropriate changes in disposition times for this large cohort of ED patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nudge Units to Improve the Delivery of Health Care
Patel, M. S., Volpp, K. G., & Asch, D. A. (2018) · New England Journal of Medicine · doi:10.1056/nejmp1712984 · Cited by 297
"Going solid": a model of system dynamics and consequences for patient safety
Cook, R. (2005) · Quality and Safety in Health Care · doi:10.1136/qshc.2003.009530 · Cited by 278
Sandoval, Y., Apple, F. S., Mahler, S. A., Body, R., Collinson, P. O., Jaffe, A. S., & on behalf of the International Federation of Clinical Chemistry and Laboratory Medicine Committee on the Clinical Application of Cardiac Biomarkers (2022) · Circulation · doi:10.1161/circulationaha.122.059678 · Cited by 202
Research works printed but not linked: 34
- Benjamin, 2017, Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association., Circulation, 135, e146, 10.1161/CIR.0000000000000485 · DOI · Paper page
- Dawson, 2023, Healthcare cost burden of acute chest pain presentations., Emerg Med J, 40, 437, 10.1136/emermed-2022-212674 · DOI
- Aalam, 2020, National trends in chest pain visits in US emergency departments (2006-2016)., Emerg Med J, 37, 696, 10.1136/emermed-2020-210306 · DOI
- Bergmark, 2022, Acute coronary syndromes., Lancet, 399, 1347, 10.1016/S0140-6736(21)02391-6 · DOI
- Bhatt, 2022, Diagnosis and Treatment of Acute Coronary Syndromes: A Review., JAMA, 327, 662, 10.1001/jama.2022.0358 · DOI
- Riley, 2017, Cost analysis of the History, ECG, Age, Risk factors, and initial Troponin (HEART) Pathway randomized control trial., Am J Emerg Med, 35, 77, 10.1016/j.ajem.2016.10.005 · DOI
- Greenslade, 2018, Diagnostic accuracy of a new high-sensitivity troponin I assay and five accelerated diagnostic pathways for ruling out acute myocardial infarction and acute coronary syndrome., Ann Emerg Med, 71, 439, 10.1016/j.annemergmed.2017.10.030 · DOI
- Lee, 2023, Initial evaluation and management of patients presenting with acute chest pain in the emergency department., Curr Cardiol Rep, 25, 1677, 10.1007/s11886-023-01984-6 · DOI
- Kontos, 2022, ACC expert consensus decision pathway on the evaluation and disposition of acute chest pain in the emergency department: a report of the American College of Cardiology Solution Set Oversight Committee., J Am Coll Cardiol, 80, 1925, 10.1016/j.jacc.2022.08.750 · DOI
- Wereski, 2021, Cardiac troponin thresholds and kinetics to differentiate myocardial injury and myocardial infarction., Circulation, 144, 528, 10.1161/CIRCULATIONAHA.121.054302 · DOI
- Cullen, 2022, Point-of-care testing with high-sensitivity cardiac troponin assays: the challenges and opportunities., Emerg Med J, 39, 861, 10.1136/emermed-2021-211907 · DOI
- Lowry, 2023, Troponin in early presenters to rule out myocardial infarction., Eur Heart J, 44, 2846, 10.1093/eurheartj/ehad376 · DOI
- Gabayan, 2015, Emergency department crowding and outcomes after emergency department discharge., Ann Emerg Med, 66, 483, 10.1016/j.annemergmed.2015.04.009 · DOI
- Rahsepar, 2022, Point-of-care tests’ role in time metrics of urgent interventions in emergency department; a systematic review of literature., Arch Acad Emerg Med, 10, e82
- Amundson, 2015, Cardiac troponin assays: a review of quantitative point-of-care devices and their efficacy in the diagnosis of myocardial infarction., Clin Chem Lab Med, 53, 665, 10.1515/cclm-2014-0837 · DOI
- Lin, 2020, How to choose a point-of-care testing for troponin., J Clin Lab Anal, 34, e23263, 10.1002/jcla.23263 · DOI
- Apple, 2021, IFCC Committee on Clinical Application of Cardiac Bio-Markers. Implementation of high-sensitivity and point-of-care cardiac troponin assays into practice: some different thoughts., Clin Chem, 67, 70, 10.1093/clinchem/hvaa264 · DOI
- Bruinen, 2022, Point-of-care high-sensitivity troponin-I analysis in capillary blood for acute coronary syndrome diagnostics., Clin Chem Lab Med, 60, 1669, 10.1515/cclm-2022-0268 · DOI
- Boeddinghaus, 2020, Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I., J Am Coll Cardiol, 75, 1111, 10.1016/j.jacc.2019.12.065 · DOI
- Sörensen, 2019, Diagnostic Evaluation of a High-Sensitivity Troponin I Point-of-Care Assay., Clin Chem, 65, 1592, 10.1373/clinchem.2019.307405 · DOI
- Zalama-Sánchez, 2024, Diagnostic performance of point-of-care high-sensitivity troponin in the exclusion of non-ST-elevation myocardial infarction in the emergency department., J Pers Med, 14, 762, 10.3390/jpm14070762 · DOI
- Garg, 2017, Cardiac biomarkers of acute coronary syndrome: from history to high-sensitivity cardiac troponin., Intern Emerg Med, 12, 147, 10.1007/s11739-017-1612-1 · DOI
- Altman, 1983, Measurement in medicine: the analysis of method comparison studies., Statistician, 32, 307, 10.2307/2987937 · DOI · Paper page
- Mohammed, 2008, Plotting basic control charts: tutorial notes for healthcare practitioners., Qual Saf Health Care, 17, 137, 10.1136/qshc.2004.012047 · DOI
- Amalberti, 2020, Managing risk in hazardous conditions: improvisation is not enough., BMJ Qual Saf, 29, 60, 10.1136/bmjqs-2019-009443 · DOI
- Pickering, 2018, Validity of a novel point-of-care troponin assay for single-test rule-out of acute myocardial infarction., JAMA Cardiol, 3, 1108, 10.1001/jamacardio.2018.3368 · DOI
- Bingisser, 2012, Cardiac troponin: a critical review of the case for point-of-care testing in the ED., Am J Emerg Med, 30, 1639, 10.1016/j.ajem.2012.03.004 · DOI
- Apple, 2004, Analytical performance of the i-STAT cardiac troponin I assay., Clin Chim Acta, 345, 123, 10.1016/j.cccn.2004.03.010 · DOI
- Tsui, 2019, Analytical concordance of diverse point-of-care and central laboratory troponin I assays., J Appl Lab Med, 3, 764, 10.1373/jalm.2018.026690 · DOI
- Grunau, 2018, Commentary: sensitivity, specificity, and predictive values: foundations, liabilities, and pitfalls in research and practice., Front Public Health, 6, 256, 10.3389/fpubh.2018.00256 · DOI
- Leeflang, 2013, Variation of a test’s sensitivity and specificity with disease prevalence., CMAJ, 185, E537, 10.1503/cmaj.121286 · DOI · Paper page
- Xu, 2019, Prevalence and predictability of low-yield inpatient laboratory diagnostic tests., JAMA Netw Open, 2, e1910967, 10.1001/jamanetworkopen.2019.10967 · DOI · Paper page
- Bentley, 2012, Implications of the impact of prevalence on test thresholds and outcomes: lessons from tuberculosis., BMC Res Notes, 5, 563, 10.1186/1756-0500-5-563 · DOI
- Macrae, 2016, The problem with incident reporting., BMJ Qual Saf, 25, 71, 10.1136/bmjqs-2015-004732 · DOI
Metadata
- Authors
- Grabinski, Z., Swartz, J. L., Wang, Y., Itani, A., Aguero-Rosenfeld, M., Sanchez, N., Gulati, R., Wittman, I. G., & Smith, S. W.
- Affiliations
- NYU Langone Health (US)
- Author Affiliations:Ronald O. Perelman Department of Emergency Medicine, New York University Grossman School of Medicine (Drs Grabinski, and Swartz, Ms Wang, and Drs Itani, Gulati, Wittman, and Smith), Department of Pathology (Dr Aguero-Rosenfeld), Clinical Laboratories (Dr Aguero-Rosenfeld and Ms Sanchez), Institute for Innovations in Medical Education, New York University Grossman School of Medicine (Dr Smith), NYU Langone Health, New York.
- Corresponding author
- Grabinski, Zoe
- Venue
- Quality Management in Health Care
- Published
- 2025-05-08
- Volume
- 35
- Issue
- 3
- Pages
- 175-182
- ISSN
- 1063-8628 (ISSN-L)
- 1550-5154
- OpenAlex
- W4410360118
- Cited by
- 0
- References
- 3
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Quality Management in Health Care (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Emergency Medicine › Emergency and Acute Care Studies
- Keywords
- acute coronary syndrome, emergency department, test turnaround time, time to disposition, diagnostic accuracy, cost reduction, electronic health record interventions, provider education, quality improvement
- MeSH terms
- Point-of-Care Testing, Emergency Service, Hospital, Humans, Time Factors, Troponin, Efficiency, Organizational, Acute Coronary Syndrome, Electronic Health Records, Quality Improvement, Patient Safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review