Objective: The aim of this study was to test the diagnostic performance of a deep learning-based triage system for the detection of acute findings in abdominal computed tomography (CT) examinations. Materials and Methods: Using a RIS/PACS (Radiology Information System/Picture Archiving and Communication System) search engine, we obtained 100 consecutive abdominal CTs with at least one of the following findings: free-gas, free-fluid, or fat-stranding and 100 control cases with absence of these findings. The CT data were analyzed using a convolutional neural network algorithm previously trained for detection of these findings on an independent sample. The validation of the results was performed on a Web-based feedback system by a radiologist with 1 year of experience in abdominal imaging without prior knowledge of image findings through both visual confirmation and comparison with the clinically approved, written report as the standard of reference. All cases were included in the final analysis, except those in which the whole dataset could not be processed by the detection software. Measures of diagnostic accuracy were then calculated. Results: A total of 194 cases were included in the analysis, 6 excluded because of technical problems during the extraction of the DICOM datasets from the local PACS. Overall, the algorithm achieved a 93% sensitivity (91/98, 7 false-negative) and 97% specificity (93/96, 3 false-positive) in the detection of acute abdominal findings. Intra-abdominal free gas was detected with a 92% sensitivity (54/59) and 93% specificity (39/42), free fluid with a 85% sensitivity (68/80) and 95% specificity (20/21), and fat stranding with a 81% sensitivity (42/50) and 98% specificity (48/49). False-positive results were due to streak artifacts, partial volume effects, and a misidentification of a diverticulum (each n = 1). Conclusions: The algorithm's autonomous detection of acute pathological abdominal findings demonstrated a high diagnostic performance, enabling guidance of the radiology workflow toward prioritization of abdominal CT examinations with acute conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rli.0000000000000509

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 83

Metadata

Authors
Winkel, D. J., Heye, T., Weikert, T. J., Boll, D. T., & Stieltjes, B.
Venue
Investigative Radiology
Published
2019-01
Volume
54
Issue
1
Pages
55-59
ISSN
  • 0020-9996 (ISSN-L)
  • 1536-0210
OpenAlex
W2891492187
Cited by
83
References
2
FWCI
1.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of an AI-Based Detection Software for Acute Findings in Abdominal Computed Tomography Scans: Toward an Automated Work List Prioritization of Routine CT Examinations. https://app.cochat.ai/papers/10.1097/rli.0000000000000509
The paper
Winkel, D. J., Heye, T., Weikert, T. J., Boll, D. T., & Stieltjes, B. (2019). Evaluation of an AI-Based Detection Software for Acute Findings in Abdominal Computed Tomography Scans: Toward an Automated Work List Prioritization of Routine CT Examinations. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000509

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.