Cited by 118AI in cancer detectionRadiomics and Machine Learning in Medical ImagingProstate Cancer Diagnosis and Treatment

A Novel Deep Learning Based Computer-Aided Diagnosis System Improves the Accuracy and Efficiency of Radiologists in Reading Biparametric Magnetic Resonance Images of the Prostate: Results of a Multireader, Multicase Study

Winkel, David J., Tong, Angela, Lou, Bin, Kamen, Ali, Comaniciu, Dorin, Disselhorst, Jonathan A., Rodríguez-Ruiz, Alejandro, Huisman, Henkjan +8 more·2021·Investigative Radiology

Abstract

OBJECTIVE: The aim of this study was to evaluate the effect of a deep learning based computer-aided diagnosis (DL-CAD) system on radiologists' interpretation accuracy and efficiency in reading biparametric prostate magnetic resonance imaging scans. MATERIALS AND METHODS: We selected 100 consecutive prostate magnetic resonance imaging cases from a publicly available data set (PROSTATEx Challenge) with and without histopathologically confirmed prostate cancer. Seven board-certified radiologists were tasked to read each case twice in 2 reading blocks (with and without the assistance of a DL-CAD), with a separation between the 2 reading sessions of at least 2 weeks. Reading tasks were to localize and classify lesions according to Prostate Imaging Reporting and Data System (PI-RADS) v2.0 and to assign a radiologist's level of suspicion score (scale from 1-5 in 0.5 increments; 1, benign; 5, malignant). Ground truth was established by consensus readings of 3 experienced radiologists. The detection performance (receiver operating characteristic curves), variability (Fleiss κ), and average reading time without DL-CAD assistance were evaluated. RESULTS: The average accuracy of radiologists in terms of area under the curve in detecting clinically significant cases (PI-RADS ≥4) was 0.84 (95% confidence interval [CI], 0.79-0.89), whereas the same using DL-CAD was 0.88 (95% CI, 0.83-0.94) with an improvement of 4.4% (95% CI, 1.1%-7.7%; P = 0.010). Interreader concordance (in terms of Fleiss κ) increased from 0.22 to 0.36 (P = 0.003). Accuracy of radiologists in detecting cases with PI-RADS ≥3 was improved by 2.9% (P = 0.10). The median reading time in the unaided/aided scenario was reduced by 21% from 103 to 81 seconds (P < 0.001). CONCLUSIONS: Using a DL-CAD system increased the diagnostic accuracy in detecting highly suspicious prostate lesions and reduced both the interreader variability and the reading time.

Integrity signals

Registry

Crossref · 10.1097/rli.0000000000000780

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A Siemens commercial prototype increased diagnostic accuracy for clinically significant prostate cancer in a retrospective reader study with seven radiologists.

    “a commercial prototype from Siemens was shown to increase the diagnostic accuracy of clinically significant prostate cancer in a retrospective reader study involving seven radiologists (37).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Winkel, D. J., Tong, A., Lou, B., Kamen, A., Comaniciu, D., Disselhorst, J. A., Rodríguez-Ruiz, A., Huisman, H., Szolar, D., Shabunin, I., Choi, M. H., Xing, P., Penzkofer, T., Grimm, R., von Busch, H., & Boll, D. T.
Affiliations
  • University Hospital of Basel (CH)
  • NYU Langone Health (US)
  • Siemens (United States) (US)
  • Siemens Healthcare AG Advanced Clinical Imaging Technology, Lausanne, Vaud, Switzerland
  • ScreenPoint Medical
  • Radboud University Medical Center (NL)
  • Diagnostikum Graz, Graz, Austria
  • Patero Clinic, Moscow, Russia
  • The Catholic University of Korea Eunpyeong St. Mary's Hospital (KR)
  • Changhai Hospital (CN)
  • Berlin Institute of Health at Charité - Universitätsmedizin Berlin (DE)
  • Siemens Healthineers (Germany) (DE)
  • Siemens Healthineers Diagnostic Imaging, Erlangen, Germany.
Corresponding author
  • Winkel, David J.
  • Shabunin, Ivan
  • Boll, Daniel T.
Venue
Investigative Radiology
Published
2021-04-02
Volume
56
Issue
10
Pages
605-613
ISSN
  • 0020-9996 (ISSN-L)
  • 1536-0210
OpenAlex
W3148634016
Cited by
118
References
37
Citations by year
2026: 14 · 2025: 34 · 2024: 22 · 2023: 24 · 2022: 15 · 2021: 9
FWCI
6.15
Type
journal article
Language
en
Open access
closed
Locations
  • Investigative Radiology (publishedVersion)
  • PubMed (publishedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
Funders
  • Universitätsspital Basel
  • Schweizerische Gesellschaft für Radiologie
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Prostate Cancer Diagnosis and Treatment
Keywords
computer-aided diagnosis, prostate cancer detection, inter-reader variability, reading time reduction, deep learning, clinically significant prostate cancer
MeSH terms
Radiologists, Deep Learning, Computers, Humans, Magnetic Resonance Imaging, Male, Prostatic Neoplasms, Retrospective Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review