CoChat

Comparison of Biexponential and Monoexponential Model of Diffusion Weighted Imaging in Evaluation of Renal Lesions: Preliminary Experience

Chandarana, Hersh, Lee, Vivian S., Hecht, Elizabeth, Taouli, Bachir, Sigmund, Eric E. · 2011 · Investigative Radiology
Cited by 188

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To obtain intravoxel incoherent motion (IVIM) parameters with biexponential analysis of multiple b-value diffusion-weighted imaging (DWI) and compare these parameters to apparent diffusion coefficient (ADC) obtained with monoexponential modeling in their ability to discriminate enhancing from nonenhancing renal lesions. MATERIALS AND METHODS: Twenty-eight patients were imaged at 1.5 T utilizing contrast-enhanced (CE) magnetic resonance imaging (MRI) and breath-hold DWI using 8 b values (range: 0-800 s/mm(2)). Perfusion fraction (f(p)), tissue diffusivity (D(t)), and pseudo-diffusion coefficient (D(p)) were calculated using segmented biexponential analysis. ADC(total) and ADC(0-400-800) were calculated with monoexponential fitting of the DWI data. f(p), D(t), D(p), ADC(total), and ADC(0-400-800) were compared between enhancing and nonenhancing renal lesions. Receiver operating characteristic analysis was performed for all DWI parameters. f(p) was correlated with percent enhancement. RESULTS: There were a total of 31 renal lesions (15 enhancing and 16 nonenhancing) in 28 patients on CE-MRI. f(p) of enhancing masses was significantly higher (27.9 vs. 6.1) and D(t) was significantly lower (1.47 vs. 2.40 ×10(-3) mm(2)/s). IVIM parameters f(p) and D(t) demonstrated higher accuracy in differentiating enhancing from nonenhancing renal lesions compared with monoexponential parameters ADC(0-400-800) and ADC(total), with area under the curve of 0.946, 0.896, 0.854, and 0.675, respectively. There was a good correlation between f(p) and percent enhancement (r = 0.7; P < 0.001). CONCLUSION: IVIM parameters f(p) and D(t) obtained with biexponential fitting of multi-b value DWI have higher accuracy compared with ADC (obtained with monoexponential fit) in discriminating enhancing from nonenhancing renal lesions. Furthermore, f(p) demonstrates good correlation with percent enhancement and can provide information regarding lesion vascularity without the use of exogenous contrast agent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rli.0b013e3181ffc485

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 188

Metadata

Authors
Chandarana, H., Lee, V. S., Hecht, E., Taouli, B., & Sigmund, E. E.
Venue
Investigative Radiology
Published
2011-05
Volume
46
Issue
5
Pages
285-291
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2050109563
Cited by
188
References
1
FWCI
12.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.