Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 226

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Intravoxel Incoherent Motion and Diffusion-Tensor Imaging in Renal Tissue under Hydration and Furosemide Flow Challenges

Sigmund, Eric E., Vivier, Pierre-Hugues, Sui, Dabang, Lamparello, Nicole A., Tantillo, Kristopher, Mikheev, Artem, Rusinek, Henry, Babb, James S., Storey, Pippa, Lee, Vivian S., Chandarana, Hersh · 2012 · Radiology

Abstract

PURPOSE: To assess the reproducibility and the distribution of intravoxel incoherent motion (IVIM) and diffusion-tensor (DT) imaging parameters in healthy renal cortex and medulla at baseline and after hydration or furosemide challenges. MATERIALS AND METHODS: Using an institutional review board-approved HIPAA-compliant protocol with written informed consent, IVIM and DT imaging were performed at 3 T in 10 volunteers before and after water loading or furosemide administration. IVIM (apparent diffusion coefficient [ADC], tissue diffusivity [D(t)], perfusion fraction [f(p)], pseudodiffusivity [D(p)]) and DT (mean diffusivity [MD], fractional anisotropy [FA], eigenvalues [λ(i)]) imaging parameters and urine output from serial bladder volumes were calculated. (a)Reproducibility was quantified with coefficient of variation, intraclass correlation coefficient, and Bland-Altman limits of agreement; (b) contrast and challenge response were quantified with analysis of variance; and (c) Pearson correlations were quantified with urine output. RESULTS: Good reproducibility was found for ADC, D(t), MD, FA, and λ(i) (average coefficient of variation, 3.7% [cortex] and 5.0% [medulla]), and moderate reproducibility was found for D(p), f(p), and f(p) · D(p) (average coefficient of variation, 18.7% [cortex] and 25.9% [medulla]). Baseline cortical diffusivities significantly exceeded medullary values except D(p), for which medullary values significantly exceeded cortical values, and λ(1,) which showed no contrast. ADC, D(t), MD, and λ(i) increased significantly for both challenges. Medullary diffusivity increases were dominated by transverse diffusion (1.72 ± 0.09 [baseline] to 1.79 ± 0.10 [hydration] μm(2)/msec, P = .0059; or 1.86 ± 0.07 [furosemide] μm(2)/msec, P = .0094). Urine output correlated with cortical ADC with furosemide (r = 0.7, P = .034) and with medullary λ(1) (r = 0.83, P = .0418), λ(2) (r = 0.85, P = .0301), and MD (r = 0.82, P = .045) with hydration. CONCLUSION: Diffusion MR metrics are sensitive to flow changes in kidney induced by diuretic challenges. The results of this study suggest that vascular flow, tubular dilation, water reabsorption, and intratubular flow all play important roles in diffusion-weighted imaging contrast.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12111327

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 226

Metadata

Authors
Sigmund, E. E., Vivier, P.-H., Sui, D., Lamparello, N. A., Tantillo, K., Mikheev, A., Rusinek, H., Babb, J. S., Storey, P., Lee, V. S., & Chandarana, H.
Venue
Radiology
Published
2012-06
Volume
263
Issue
3
Pages
758-769
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2073117372
Cited by
226
References
1
FWCI
13.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intravoxel Incoherent Motion and Diffusion-Tensor Imaging in Renal Tissue under Hydration and Furosemide Flow Challenges. https://app.cochat.ai/papers/10.1148/radiol.12111327
The paper
Sigmund, E. E., Vivier, P.-H., Sui, D., Lamparello, N. A., Tantillo, K., Mikheev, A., Rusinek, H., Babb, J. S., Storey, P., Lee, V. S., & Chandarana, H. (2012). Intravoxel Incoherent Motion and Diffusion-Tensor Imaging in Renal Tissue under Hydration and Furosemide Flow Challenges. Radiology. https://doi.org/10.1148/radiol.12111327

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.