Magnetic Resonance–Based Attenuation Correction for PET/MR Hybrid Imaging Using Continuous Valued Attenuation Maps
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Attenuation correction of positron emission tomographic (PET) data is critical in providing accurate and quantitative PET volumes. Deriving an attenuation map (μ-map) from magnetic resonance (MR) volumes is a challenge in PET/MR hybrid imaging. The difficulty lies in differentiating cortical bone from air from standard MR sequences because both these classes yield little to no MR signal and thus shows no distinguishable information. The objective of this contribution is 2-fold: (1) to generate and evaluate a continuous valued computed tomography (CT)-like attenuation map (μ-map) with continuous density values from dedicated MR sequences and (2) to compare its PET quantification accuracy with respect to a CT-based attenuation map as the criterion standard and other segmentation-based attenuation maps for studies of the head. MATERIALS AND METHODS: Three-dimensional Dixon-volume interpolated breath-hold examination and ultrashort echo time sequences were acquired for each patient on a Siemens 3-T Biograph mMR PET/MR hybrid system and the corresponding patient CT on a Siemens Biograph 64. A pseudo-CT training was done using the epsilon-insensitive support vector regression ([Latin Small Letter Open E]-SVR) technique on 5 patients who had CT/MR/PET triplets, and the generated model was evaluated on 5 additional patients who were not included in the training process. Four μ-maps were compared, and 3 of them derived from CT: scaled CT (μ-map CT), 3-class segmented CT without cortical bone (μ-map no bone), 4-class segmented CT with cortical bone (μ-map bone), and 1 from MR sequences via [Latin Small Letter Open E]-SVR technique previously mentioned (ie, MR predicted [μ-map MR]). Positron emission tomographic volumes with each of the previously mentioned μ-maps were reconstructed, and relative difference images were calculated with respect to μ-map CT as the criterion standard. RESULTS: For PET quantification, the proposed method yields a mean (SD) absolute error of 2.40% (3.69%) and 2.16% (1.77%) for the complete brain and the regions close to the cortical bone, respectively. In contrast, PET using μ-map no bone yielded 10.15% (3.31%) and 11.03 (2.26%) for the same, although PET using μ-map bone resulted in errors of 3.96% (3.71%) and 4.22% (3.91%). Furthermore, it is shown that the model can be extended to predict pseudo-CTs for other anatomical regions on the basis of only MR information. CONCLUSIONS: In this study, the generation of continuous valued attenuation maps from MR sequences is demonstrated and its effect on PET quantification is evaluated in comparison with segmentation-based μ-maps. A less-than-2-minute acquisition time makes the proposed approach promising for a clinical application for studies of the head. However, further experiments are required to validate and evaluate this technique for attenuation correction in other regions of the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311 · cited 1×
“All registrations were performed using the software elastix.(22) In a patient setup, however, the registration is not necessary because the CT images are only needed for an initial training.”
MethodPET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418 · cited 1×
“The advent of hybrid positron emission tomography (PET)/ magnetic resonance (MR) systems has opened up the possibility to combine 2 powerful imaging modalities in 1 hybrid imaging device.(1,2) Magnetic resonance imaging (MRI), on the one hand, is known for its excellent soft tissue contrast by means of a plethora of i…”
BackgroundSamarin, A., Burger, C., Wollenweber, S. D., Crook, D. W., Burger, I. A., Schmid, D. T., von Schulthess, G. K., & Kuhn, F. P. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2113-0 · Cited by 251 · cited 2×
“This decrease is also in agreement with errors 10% to 15% underestimation reported by Schramm et al,11 Samarin et al,12 and Catana et al,13 reiterating the inclusion of a cortical bone class when deriving K-maps.”
BackgroundResult
Cited by
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
A review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain Studies
Burgos, N., Cardoso, M. J., Thielemans, K., Modat, M., Pedemonte, S., Dickson, J., Barnes, A., Ahmed, R., Mahoney, C. J., Schott, J. M., et al. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2340135 · Cited by 364
Izquierdo-Garcia, D., Hansen, A. E., Förster, S., Benoit, D., Schachoff, S., Fürst, S., Chen, K. T., Chonde, D. B., & Catana, C. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.136341 · Cited by 218
“Results similar to ours were also presented by Johansson et al. and Larsson et al. with a machine learning method based on a mixture of gaussians ( 29,30 ) and by Navalpakkam et al. with a support vector machine ( 31 ).”
MethodPaulus, D. H., Quick, H. H., Geppert, C., Fenchel, M., Zhan, Y., Hermosillo, G., Faul, D., Boada, F., Friedman, K. P., & Koesters, T. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.156000 · Cited by 175
“For head imaging, several approaches have been proposed to include cortical bone as an attenuation class using either a combination of atlas registration and pattern recognition (15) or pseudo CTs generated with an ultrashort echo time MR sequence (16).”
MethodSelf-citation
Metadata
- Authors
- Navalpakkam, B. K., Braun, H., Kuwert, T., & Quick, H. H.
- Venue
- Investigative Radiology
- Published
- 2013-05
- Volume
- 48
- Issue
- 5
- Pages
- 323-332
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2154346707
- Cited by
- 123
- References
- 3
- FWCI
- 14.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.