CoChat

Undetectable Thyroglobulin in Patients With Differentiated Thyroid Carcinoma and Residual Radioiodine Uptake on a Postablation Whole-Body Scan

Giovanella, Luca, Suriano, Sergio, Ceriani, Luca, Verburg, Frederik Anton · 2011 · Clinical Nuclear Medicine
Cited by 57

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

AIM: To assess the impact of laboratory interferences and pitfalls in producing falsely undetectable Tg in differentiated thyroid carcinoma (DTC) patients with residual iodine-avid thyroid tissue on a posttreatment whole-body scan (PT-WBS). METHODS: From 298 consecutive patients with histologically proven DTC, 47 patients (16%) with undetectable serum Tg but residual ¹³¹I uptake on a PT-WBS were selected. Interferences from antithyroglobulin antibodies (TgAb), heterophile antibodies, and hook-effects were screened; in the remaining samples, serum Tg was measured in 3 different immunoassays. RESULTS: Of 47 patients, 11 (23%) showed interference from either thyroglobulin antibodies (n = 10) or heterophile antibodies (n = 1). Among the 36 remaining patients, 18 showed detectable Tg levels after retesting using a different immunoassay, whereas the remaining 18 patients also showed detectable Tg levels in a third Tg immunoassay. However, only 7 patients showed a detectable Tg in both secondarily used assays. Tg levels remained undetectable in all methods in 9 patients (19%) even after extensive laboratory work-up and despite the presence of ¹³¹I-avid tissue found in PT-WBS. CONCLUSIONS: A careful assessment of interferences in Tg measurement significantly reduced the occurrence of undetectable Tg among patients with ¹³¹I uptake in PT-WBS. However, such extensive assessment is difficult in clinical practice and one-fifth of patients still had undetectable Tg in multiple assays despite an intensive laboratory work-up. A benchmark between ¹³¹I imaging and Tg measurement authenticates the interpretation of Tg measurements and, consequently, remains of pivotal value by authenticating the use of serum Tg during further follow-up of DTC patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rlu.0b013e318203bb84

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 57

Metadata

Authors
Giovanella, L., Suriano, S., Ceriani, L., & Verburg, F. A.
Venue
Clinical Nuclear Medicine
Published
2011-02
Volume
36
Issue
2
Pages
109-112
ISSN
0363-9762 (ISSN-L)
OpenAlex
W2312650245
Cited by
57
References
2
FWCI
3.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Undetectable Thyroglobulin in Patients With Differentiated Thyroid Carcinoma and Residual Radioiodine Uptake on a Postablation Whole-Body Scan. https://app.cochat.ai/papers/10.1097/rlu.0b013e318203bb84
The paper
Giovanella, L., Suriano, S., Ceriani, L., & Verburg, F. A. (2011). Undetectable Thyroglobulin in Patients With Differentiated Thyroid Carcinoma and Residual Radioiodine Uptake on a Postablation Whole-Body Scan. Clinical Nuclear Medicine. https://doi.org/10.1097/rlu.0b013e318203bb84

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.