Impact of Time-of-Flight and Point-Spread-Function in SUV Quantification for Oncological PET
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accuracy in the quantification of the SUV is a critical point in PET because proper quantification of tumor uptake is essential for therapy monitoring and prognosis evaluation. Recent advances such as time-of-flight (TOF) and point-spread-function (PSF) reconstructions have dramatically improved detectability. However, first experiences with these techniques have shown a consistent tendency to measure markedly high SUV values, bewildering nuclear medicine physicians and referring clinicians. PURPOSE: We investigated different reconstruction and quantification procedures to determine the optimum protocol for an accurate SUV quantification in last generation PET scanners. METHODS: Both phantom and patient images were evaluated. A complete set of experiments was performed using a body phantom containing 6 spheres with different background levels and contrasts. Whole-body FDG PET/CT of 20 patients with breast and lung cancer was evaluated. One hundred five foci were identified by 2 experienced nuclear medicine physicians.Each acquisition was reconstructed both with classical and advanced (TOF, PSF) reconstruction techniques. Each sphere and each in vivo lesion was quantified with different parameters as follows: SUV(max), SUV(mean), and SUV(50) (mean within a 50% isocontour). RESULTS: This study has confirmed that quantification with SUV(max) produces important overestimation of metabolism in new generation PET scanners. This is a relevant result because, currently, SUV(max) is the standard parameter for quantification. SUV(50) has been shown as the best alternative, especially when applied to images reconstructed with PSF + TOF. CONCLUSIONS: SUV(50) provides accurate quantification and should replace SUV(max) in PET tomographs incorporating advanced reconstruction techniques. PSF + TOF reconstruction is the optimum for both detection and accurate quantification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Reducing between scanner differences in multi-center PET studies
Joshi, A., Koeppe, R. A., & Fessler, J. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.057 · Cited by 247
Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142 · cited 1×
“This effect has been previously reported and usually referred to as ‘‘ringing’’ or ‘‘Gibbs-type’’ artifacts.(4) Both effects produced errors in SUVmax quantification greater that 200% in some cases (Fig.”
BackgroundVariations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136 · cited 1×
“Particularly, according to published survey, SUVmax is informed in 91% of sites where SUV is included in the patient report.(12) This overestimation produced in newgeneration PET scanners has been previously described(6,8) and attributed to 2 main effects as follows: a higher level of noise in smaller voxels and the G…”
Background
Cited by
Prospective of 68Ga-Radiopharmaceutical Development
Velikyan, I. (2014) · Theranostics · doi:10.7150/thno.7447 · Cited by 336
Schwenck, J., Rempp, H., Reischl, G., Kruck, S., Stenzl, A., Nikolaou, K., Pfannenberg, C., & la Fougère, C. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3490-6 · Cited by 269
Johnbeck, C. B., Knigge, U., & Kjær, A. (2014) · Future Oncology · doi:10.2217/fon.14.139 · Cited by 191
PET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105
“The combination of TOF and PSF thus represents a further potential step towards improvement of PET reconstruction [45–49] (Fig.”
BackgroundNew PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
Metadata
- Authors
- Prieto, E., Domínguez-Prado, I., García-Velloso, M. J., Peñuelas, I., Richter, J. Á., & Martí-Climent, J. M.
- Venue
- Clinical Nuclear Medicine
- Published
- 2013-02
- Volume
- 38
- Issue
- 2
- Pages
- 103-109
- ISSN
- 0363-9762 (ISSN-L)
- OpenAlex
- W2000915790
- Cited by
- 74
- References
- 4
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.