CoChat

Impact of Time-of-Flight and Point-Spread-Function in SUV Quantification for Oncological PET

Prieto, Elena, Domínguez-Prado, Inés, García-Velloso, María José, Peñuelas, Iván, Richter, José Ángel, Martí-Climent, Josep Maria · 2013 · Clinical Nuclear Medicine
Cited by 74

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Accuracy in the quantification of the SUV is a critical point in PET because proper quantification of tumor uptake is essential for therapy monitoring and prognosis evaluation. Recent advances such as time-of-flight (TOF) and point-spread-function (PSF) reconstructions have dramatically improved detectability. However, first experiences with these techniques have shown a consistent tendency to measure markedly high SUV values, bewildering nuclear medicine physicians and referring clinicians. PURPOSE: We investigated different reconstruction and quantification procedures to determine the optimum protocol for an accurate SUV quantification in last generation PET scanners. METHODS: Both phantom and patient images were evaluated. A complete set of experiments was performed using a body phantom containing 6 spheres with different background levels and contrasts. Whole-body FDG PET/CT of 20 patients with breast and lung cancer was evaluated. One hundred five foci were identified by 2 experienced nuclear medicine physicians.Each acquisition was reconstructed both with classical and advanced (TOF, PSF) reconstruction techniques. Each sphere and each in vivo lesion was quantified with different parameters as follows: SUV(max), SUV(mean), and SUV(50) (mean within a 50% isocontour). RESULTS: This study has confirmed that quantification with SUV(max) produces important overestimation of metabolism in new generation PET scanners. This is a relevant result because, currently, SUV(max) is the standard parameter for quantification. SUV(50) has been shown as the best alternative, especially when applied to images reconstructed with PSF + TOF. CONCLUSIONS: SUV(50) provides accurate quantification and should replace SUV(max) in PET tomographs incorporating advanced reconstruction techniques. PSF + TOF reconstruction is the optimum for both detection and accurate quantification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rlu.0b013e318279b9df

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 74

Metadata

Authors
Prieto, E., Domínguez-Prado, I., García-Velloso, M. J., Peñuelas, I., Richter, J. Á., & Martí-Climent, J. M.
Venue
Clinical Nuclear Medicine
Published
2013-02
Volume
38
Issue
2
Pages
103-109
ISSN
0363-9762 (ISSN-L)
OpenAlex
W2000915790
Cited by
74
References
4
FWCI
6.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.