Cited by 76Medical Imaging Techniques and ApplicationsRadiomics and Machine Learning in Medical ImagingLung Cancer Diagnosis and Treatment

Variance of SUVs for FDG-PET/CT is Greater in Clinical Practice Than Under Ideal Study Settings

Open access
Kumar, Virendra, Nath, Kavindra, Berman, Claudia G., Kim, Jongphil, Tanvetyanon, Tawee, Chiappori, Alberto A., Gatenby, Robert A., Gillies, Robert J. +1 more·2013·Clinical Nuclear Medicine

Abstract

PURPOSE: Measurement variance affects the clinical effectiveness of PET-based measurement as a semiquantitative imaging biomarker for cancer response in individual patients and for planning clinical trials. In this study, we measured test-retest reproducibility of SUV measurements under clinical practice conditions and recorded recognized deviations from protocol compliance. METHODS: Instrument performance calibration, display, and analyses conformed to manufacture recommendations. Baseline clinical (18)F-FDG PET/CT examinations were performed and then repeated at 1 to 7 days. Intended scan initiation uptake period was to repeat the examinations at the same time for each study after injection of 12 mCi FDG tracer. Avidity of uptake was measured in 62 tumors in 21 patients as SUV for maximum voxel (SUV(max)) and for a mean of sampled tumor voxels (SUV(mean)). RESULTS: The range of SUV(max) and SUV(mean) was 1.07 to 21.47 and 0.91 to 14.69, respectively. Intraclass correlation coefficient between log of SUV(max) and log of SUV(mean) was 0.93 (95% confidence interval [CI], 0.88-0.95) and 0.92 (95% CI, 0.87-0.95), respectively.Correlation analysis failed to show an effect on uptake period variation on SUV measurements between the 2 examinations, suggesting additional sources of noise.The threshold criteria for relative difference from baseline for the 95% CI were ± 49% or ± 44% for SUV(max) or SUV(mean), respectively. CONCLUSIONS: Variance of SUV for FDG-PET/CT in current clinical practice in a single institution was greater than expected when compared with benchmarks reported under stringent efficacy study settings. Under comparable clinical practice conditions, interpretation of changes in tumor avidity in individuals and assumptions in planning clinical trials may be affected.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rlu.0b013e318279ffdf

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Lesion SUVs in [18F]FDG-PET show a test-retest variability in the same patient with the same PET scanner of up to 20% and are usually even less comparable between different scanners and centers or under routine clinical conditions.

    “However, lesion SUVs in [18F]FDG-PET show a test-retest variability in the same patient with the same PET scanner of up to 20% [189] and are usually even less comparable between different scanners and centers or under routine clinical conditions [190].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [190]

    The Conclusion reports that SUV test–retest variance in routine clinical practice was greater than benchmarks from stringent study settings, with agreement thresholds approaching 50%. The Discussion cautions about comparisons across institutions, but does not establish that measurements from different scanners or centers are usually less comparable. The 20% same-scanner figure belongs to citation [189], not the citation assessed here. (LLM, conf=0.83)

    Experimental — accuracy not yet measured
  • Using quantitative PET for patient selection is difficult in clinical practice because SUV measurements not obtained in a well-conducted clinical trial are subject to variability due to technical factors such as the PET scanner used and the acquisition and reconstruction parameters.

    “Using quantitative PET for patient selection is difficult in clinical practice because SUV measurements not obtained in a well-conducted clinical trial are subject to variability. This is because of technical factors such as the PET scanner used and the acquisition and reconstruction parameters (23–26).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

5 of the 62 references couldn’t be matched to a known paper.

Research works printed but not linked: 1

  1. [49]Doot R Kurland B Kinahan P Considerations for using PET as a response measure in multicenter clinical trials. 2009 Soc Nuclear Med 537 PMC3251737 22104290

Cited by

Sorted by citations

Authors
Kumar, V., Nath, K., Berman, C. G., Kim, J., Tanvetyanon, T., Chiappori, A. A., Gatenby, R. A., Gillies, R. J., & Eikman, E. A.
Affiliations
Moffitt Cancer Center (US)
Corresponding author
  • Kumar, Virendra
  • Nath, Kavindra
  • Gillies, Robert J.
Venue
Clinical Nuclear Medicine
Published
2013-03
Volume
38
Issue
3
Pages
175-182
ISSN
0363-9762 (ISSN-L)
OpenAlex
W113645134
Cited by
76
References
62
Citations by year
2025: 4 · 2024: 4 · 2023: 7 · 2022: 6 · 2021: 4 · 2020: 5 · 2019: 8 · 2018: 7 · 2017: 7 · 2016: 12 · 2015: 6 · 2014: 5 · 2013: 1
FWCI
6.20
Type
journal article
Language
en
Open access
Locations
  • Clinical Nuclear Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Bristol-Myers Squibb
  • Moffitt Cancer Center
  • National Institutes of Health
  • National Cancer Institute (U54CA143970, R01CA125627, U01CA143062, R01CA077575)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
Keywords
FDG PET/CT, standardized uptake value, test-retest reproducibility, tumor uptake, protocol adherence, clinical trial design, imaging biomarkers
MeSH terms
Adult, Aged, Analysis of Variance, Biological Transport, Female, Humans, Image Interpretation, Computer-Assisted, Male, Middle Aged, Neoplasms, Retrospective Studies, Tomography, X-Ray Computed, Multicenter Studies as Topic, Fluorodeoxyglucose F18, Guideline Adherence, Positron-Emission Tomography, Multimodal Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review