CoChat

ACR Appropriateness Criteria® Right Lower Quadrant Pain—Suspected Appendicitis

Smith, Martin P., Katz, Douglas S., Lalani, Tasneem, Carucci, Laura R., Cash, Brooks D., Kim, David H., Piorkowski, Robert J., Small, William C., Spottswood, Stephanie E., Tulchinsky, Mark, Yaghmai, Vahid, Yee, Judy, Rosen, Max P. · 2015 · Ultrasound Quarterly
Cited by 200

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

The most common cause of acute right lower quadrant (RLQ) pain requiring surgery is acute appendicitis (AA). This narrative's focus is on imaging procedures in the diagnosis of AA, with consideration of other diseases causing RLQ pain. In general, Computed Tomography (CT) is the most accurate imaging study for evaluating suspected AA and alternative etiologies of RLQ pain. Data favor intravenous contrast use for CT, but the need for enteric contrast when intravenous contrast is used is not strongly favored. Radiation exposure concerns from CT have led to increased investigation in minimizing CT radiation dose while maintaining diagnostic accuracy and in using algorithms with ultrasound as a first imaging examination followed by CT in inconclusive cases. In children, ultrasound is the preferred initial examination, as it is nearly as accurate as CT for the diagnosis of AA in this population and without ionizing radiation exposure. In pregnant women, ultrasound is preferred initially with MRI as a second imaging examination in inconclusive cases, which is the majority.The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every three years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances where evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ruq.0000000000000118

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 200

Metadata

Authors
Smith, M. P., Katz, D. S., Lalani, T., Carucci, L. R., Cash, B. D., Kim, D. H., Piorkowski, R. J., Small, W. C., Spottswood, S. E., Tulchinsky, M., Yaghmai, V., Yee, J., & Rosen, M. P.
Venue
Ultrasound Quarterly
Published
2015-06
Volume
31
Issue
2
Pages
85-91
ISSN
0894-8771 (ISSN-L)
OpenAlex
W2058346215
Cited by
200
References
39
FWCI
25.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ACR Appropriateness Criteria® Right Lower Quadrant Pain—Suspected Appendicitis. https://app.cochat.ai/papers/10.1097/ruq.0000000000000118
The paper
Smith, M. P., Katz, D. S., Lalani, T., Carucci, L. R., Cash, B. D., Kim, D. H., Piorkowski, R. J., Small, W. C., Spottswood, S. E., Tulchinsky, M., Yaghmai, V., Yee, J., & Rosen, M. P. (2015). ACR Appropriateness Criteria® Right Lower Quadrant Pain—Suspected Appendicitis. Ultrasound Quarterly. https://doi.org/10.1097/ruq.0000000000000118

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.