Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Cone-Beam Computed Tomography Triple Scan Procedure to Obtain a Three-Dimensional Augmented Virtual Skull Model Appropriate for Orthognathic Surgery Planning

Swennen, Gwen R. J., Mollemans, Wouter, De Clercq, Calix, Abeloos, Johan, Lamoral, Philippe, Lippens, Frank, Neyt, Nathalie, Casselman, Jan, Schutyser, Filip · 2009 · Journal of Craniofacial Surgery

Abstract

The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan procedure with triple voxel-based rigid registration was evaluated and validated on 10 orthognathic patients. First, the patient was scanned vertically with a wax bite wafer in place (CBCT scan No1). Second, a limited dose scan of the patient with a Triple Tray AlgiNot impression in place was carried out (CBCT scan No2). Finally, a high-resolution scan of the Triple Tray AlgiNot impression was done (CBCT scan No3). Sequential and semiautomatic triple voxel-based rigid registration (RNo1-RNo3) was performed to augment the patient's skull model with accurate occlusal and intercuspidation data (Maxilim, version 2.1.1., Medicim NV, Mechelen, Belgium). All registrations were based on the Maximisation of Mutual Information registration algorithm. Because the accuracy and stability of the voxel-based registration (RNo1) between the Triple Tray AlgiNot impression scan and the limited low-dose patient scan were not known, this particular registration step needed to be validated. The accuracy of registration was measured on a synthetic skull and showed to be highly accurate. A volume overlap of 98.1% was found for registered impression scan No1. The mean distance between registered impression scan No1 and registered impression scan No2 was 0.08 +/- 0.03 mm (range, 0.04-0.11 mm). As far as the stability of registration was concerned, successful registration with a stable optimal position was obtained with a maximum variability of less than 0.1 mm. The results of this study showed that semiautomatic sequential triple voxel-based rigid registration of the triple CBCT scans augmented the 3-D virtual skull model with detailed occlusal and intercuspidation data in a highly accurate and robust way. The method is therefore appropriate and valid for 3-D virtual orthognathic surgery planning in the clinical routine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/scs.0b013e3181996803

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 216

Metadata

Authors
Swennen, G. R. J., Mollemans, W., De Clercq, C., Abeloos, J., Lamoral, P., Lippens, F., Neyt, N., Casselman, J., & Schutyser, F.
Venue
Journal of Craniofacial Surgery
Published
2009-03
Volume
20
Issue
2
Pages
297-307
ISSN
1049-2275 (ISSN-L)
OpenAlex
W1971957683
Cited by
216
References
1
FWCI
10.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Cone-Beam Computed Tomography Triple Scan Procedure to Obtain a Three-Dimensional Augmented Virtual Skull Model Appropriate for Orthognathic Surgery Planning. https://app.cochat.ai/papers/10.1097/scs.0b013e3181996803
The paper
Swennen, G. R. J., Mollemans, W., De Clercq, C., Abeloos, J., Lamoral, P., Lippens, F., Neyt, N., Casselman, J., & Schutyser, F. (2009). A Cone-Beam Computed Tomography Triple Scan Procedure to Obtain a Three-Dimensional Augmented Virtual Skull Model Appropriate for Orthognathic Surgery Planning. Journal of Craniofacial Surgery. https://doi.org/10.1097/scs.0b013e3181996803

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.