CoChat

Serial Changes in Plasma Total Cortisol, Plasma Free Cortisol, and Tissue Cortisol Activity in Patients With Septic Shock: An Observational Study

Cohen, Jeremy, Smith, Melissa Lassig, Deans, Renae V., Pretorius, Carel J., Ungerer, Jacobus P.J., Tan, Terrence, Jones, Mark, Venkatesh, Bala · 2012 · Shock
Cited by 42

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Published data on adrenocortical function in septic shock have enrolled patients at various stages of critical illness and predominantly used plasma total cortisol, with minimal information on serial changes. Moreover, plasma free cortisol and tissue corticosteroid activity may not be strongly associated; however, few published data exist. The aim of this prospective observational study was to investigate serial changes in plasma total and free cortisol and tissue cortisol activity in septic shock. Twenty-nine adult patients admitted with septic shock to a tertiary-level intensive care unit were enrolled. A low-dose corticotropin test was performed on day 1. Plasma total and free cortisol, cortisone, transcortin, and urinary free cortisol and cortisone were analyzed on days 1 to 5, 7, and 10. Urinary and plasma cortisol-cortisone ratios (F:E ratio) were calculated as indices of 11-β hydroxysteroid dehydrogenase 2 and global 11-β hydroxysteroid dehydrogenase activity, respectively. Baseline total and free plasma cortisol values from 10 healthy control subjects were obtained for comparative analysis. Baseline plasma total and free cortisol levels were significantly higher than controls (457.8 ± 193 vs. 252 ± 66 nmol/L, P = 0.0002; and 50.83 ± 43.19 vs. 6.4 ± 3.2, P < 0.0001, respectively). Plasma free cortisol rose proportionately higher than total cortisol (124% ± 217.3% vs. 40% ± 33.2%, P = 0.007) following corticotropin. Baseline plasma and urinary F:E ratios were elevated over the reference ranges (13.13 ± 1.5, 1.69 ± 2.8) and were not correlated with plasma free cortisol values (r = 0.2, 0.3 respectively). Over the study period, total cortisol levels and plasma F:E ratios remained elevated, whereas plasma free cortisol levels and urinary F:E ratio declined. At baseline, plasma free cortisol levels were higher in patients who subsequently survived (23.7 ± 10.5 vs. 57.9 ± 45.8 nmol/L, P = 0.04). In septic shock, there is a differential response of plasma total and free cortisol over time and in response to corticotropin. Changes in plasma and urinary F:E ratios suggest tissue modulation of 11-β hydroxysteroid dehydrogenase activity. Total plasma cortisol measurements may not reflect the global adrenal response in septic shock.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/shk.0b013e318239b809

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 42

Metadata

Authors
Cohen, J., Smith, M. L., Deans, R. V., Pretorius, C. J., Ungerer, J. P. J., Tan, T., Jones, M., & Venkatesh, B.
Venue
Shock
Published
2012-01
Volume
37
Issue
1
Pages
28-33
ISSN
1073-2322 (ISSN-L)
OpenAlex
W2033956821
Cited by
42
References
6
FWCI
4.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Serial Changes in Plasma Total Cortisol, Plasma Free Cortisol, and Tissue Cortisol Activity in Patients With Septic Shock: An Observational Study. https://app.cochat.ai/papers/10.1097/shk.0b013e318239b809
The paper
Cohen, J., Smith, M. L., Deans, R. V., Pretorius, C. J., Ungerer, J. P. J., Tan, T., Jones, M., & Venkatesh, B. (2012). Serial Changes in Plasma Total Cortisol, Plasma Free Cortisol, and Tissue Cortisol Activity in Patients With Septic Shock: An Observational Study. Shock. https://doi.org/10.1097/shk.0b013e318239b809

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.