CoChat

Managing the Prevention of Retained Surgical Instruments: What Is the Value of Counting?

Egorova, Natalia N., Moskowitz, Alan, Gelijns, Annetine, Weinberg, Alan, Curty, James, Rabin-Fastman, Barbara, Kaplan, Harold, Cooper, Mary, Fowler, Dennis, Emond, Jean C., Greco, Giampaolo · 2008 · Annals of Surgery
Cited by 175

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

In Brief Objective: Preventing retained foreign bodies is critical for patient safety. However, the value of counting surgical instruments and the reliability of the information provided have never been quantified. This study examines the diagnostic characteristics of counting and its impact on surgical costs. Methods: We examined data from the Medical Event Reporting System-Total HealthSystem (MERS-TH), administrative hospital, and the New York State Cardiac Surgery Report databases (2000–2004). The cost per count discrepancy was examined by studying a cohort of patients undergoing coronary artery bypass graft (CABG) surgery. Linear and logistic multivariable regression models were used for statistical analysis. Results: Of 153,263 operations, there were 1062 count discrepancies. The rate of retained items was 1 of 7000 surgeries or 1 of 70 discrepancy cases. Final count discrepancies identified 77% and prevented 54% of retained items. The sensitivity of counting was 77.2%, specificity was 99.2%, but the positive predictive value was only 1.6%. Count discrepancies increased with surgery duration, late time procedures, and number of nursing teams. Bypass time, intravenous nitroglycerin injections, or myocardial infarction in the previous 24 hours were independent predictors of count discrepancies in CABG surgery. The incremental OR cost for CABG because of a count discrepancy was $932. Nationally, this would amount to an additional $24 million/yr in OR CABG cost. Conclusions: This study, for the first time, quantifies the diagnostic accuracy of counting and defines the parameters against which alternative strategies of prevention should be measured, before being adopted in standard practice. Reviewing 153,263 surgeries (2000–2004), we examined the diagnostic characteristics of surgical counts to prevent retained foreign bodies and analyzed the predictors and cost impact of count discrepancies. Predictors included late procedures, surgery duration, number of nursing teams involved, and, in coronary artery bypass graft surgeries, emergency or urgent cases. The sensitivity of counting was 77.2%, specificity was 99.2%, but the positive predictive value was only 1.6%, which created a benchmark against which alternative strategies can be tested.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/sla.0b013e3180f633be

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Egorova, N. N., Moskowitz, A., Gelijns, A., Weinberg, A., Curty, J., Rabin-Fastman, B., Kaplan, H., Cooper, M., Fowler, D., Emond, J. C., & Greco, G.
Venue
Annals of Surgery
Published
2008-01
Volume
247
Issue
1
Pages
13-18
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2060240518
Cited by
175
References
10
FWCI
21.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.