Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,092

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Risk Factors for Retained Instruments and Sponges after Surgery

Open access
Gawande, Atul A., Studdert, David M., Orav, E. John, Brennan, Troyen A., Zinner, Michael J.·2003·New England Journal of Medicine

Abstract

BACKGROUND: Risk factors for medical errors remain poorly understood. We performed a case-control study of retained foreign bodies in surgical patients in order to identify risk factors for this type of error. METHODS: We reviewed the medical records associated with all claims or incident reports of a retained surgical sponge or instrument filed between 1985 and 2001 with a large malpractice insurer representing one third of the physicians in Massachusetts. For each case, we identified an average of four randomly selected controls who underwent the same type of operation during the same six-month period. RESULTS: Our study included 54 patients with a total of 61 retained foreign bodies (of which 69 percent were sponges and 31 percent instruments) and 235 control patients. Thirty-seven of the patients with retained foreign bodies (69 percent) required reoperation, and one died. Patients with retained foreign bodies were more likely than controls to have had emergency surgery (33 percent vs. 7 percent, P<0.001) or an unexpected change in surgical procedure (34 percent vs. 9 percent, P<0.001). Patients with retained foreign bodies also had a higher mean body-mass index and were less likely to have had counts of sponges and instruments performed. In multivariate analysis, factors associated with a significantly increased risk of retention of a foreign body were emergency surgery (risk ratio, 8.8 [95 percent confidence interval, 2.4 to 31.9]), unplanned change in the operation (risk ratio, 4.1 [95 percent confidence interval, 1.4 to 12.4]), and body-mass index (risk ratio for each one-unit increment, 1.1 [95 percent confidence interval, 1.0 to 1.2]). CONCLUSIONS: The risk of retention of a foreign body after surgery significantly increases in emergencies, with unplanned changes in procedure, and with higher body-mass index. Case--control analysis of medical-malpractice claims may identify and quantify risk factors for specific types of errors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmsa021721

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 1,092

Metadata

Authors
Gawande, A. A., Studdert, D. M., Orav, E. J., Brennan, T. A., & Zinner, M. J.
Venue
New England Journal of Medicine
Published
2003-01-16
Volume
348
Issue
3
Pages
229-235
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2119880306
Cited by
1,092
References
11
FWCI
44.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk Factors for Retained Instruments and Sponges after Surgery. https://app.cochat.ai/papers/10.1056/nejmsa021721
The paper
Gawande, A. A., Studdert, D. M., Orav, E. J., Brennan, T. A., & Zinner, M. J. (2003). Risk Factors for Retained Instruments and Sponges after Surgery. New England Journal of Medicine. https://doi.org/10.1056/nejmsa021721

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.