CoChat

Differentiation of Biologic Scaffold Materials Through Physicomechanical, Thermal, and Enzymatic Degradation Techniques

Deeken, Corey R., Eliason, Braden J., Pichert, Matthew D., Grant, Sheila A., Frisella, Margaret M., Matthews, Brent D. · 2012 · Annals of Surgery
Cited by 106

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of this study was to characterize the physicomechanical, thermal, and degradation properties of several types of biologic scaffold materials to differentiate between the various materials. BACKGROUND: As more biologic scaffold materials arrive on the market, it is critical that surgeons understand the properties of each material and are provided with resources to determine the suitability of these products for specific applications such as hernia repair. METHODS: Twelve biologic scaffold materials were evaluated, including crosslinked and non-crosslinked; those of bovine, human, and porcine origin; and derivatives of pericardium, dermis, and small intestine submucosa. Physicomechanical, thermal, and degradation properties were evaluated through biomechanical testing, modulated differential scanning calorimetry, and collagenase digestion assays, respectively. Biomechanical testing included suture retention, tear strength, uniaxial tensile, and ball burst techniques. RESULTS: All scaffolds exhibited suture retention strengths greater than 20 N, but only half of the scaffolds exhibited tear resistance greater than 20 N, indicating that some scaffolds may not provide adequate resistance to tearing. A wide range of burst strengths were observed ranging from 66.2 ± 10.8 N/cm for Permacol to 1,028.0 ± 199.1 N/cm for X-Thick AlloDerm, and all scaffolds except SurgiMend, Strattice, and CollaMend exhibited strains in the physiological range of 10% to 30% (at a stress of 16 N/cm). Thermal analysis revealed differences between crosslinked and non-crosslinked materials with crosslinked bovine pericardium and porcine dermis materials exhibiting a higher melting temperature than their non-crosslinked counterparts. Similarly, the collagenase digestion assay revealed that crosslinked bovine pericardium materials resisted enzymatic degradation significantly longer than non-crosslinked bovine pericardium. CONCLUSIONS: Although differences were observed because of cross-linking, some crosslinked and non-crosslinked materials exhibited very similar properties. Variables other than cross-linking, such as decellularization/sterilization treatments or species/tissue type also contribute to the properties of the scaffolds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/sla.0b013e3182445341

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 106

Metadata

Authors
Deeken, C. R., Eliason, B. J., Pichert, M. D., Grant, S. A., Frisella, M. M., & Matthews, B. D.
Venue
Annals of Surgery
Published
2012-03
Volume
255
Issue
3
Pages
595-604
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2327470680
Cited by
106
References
2
FWCI
9.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Differentiation of Biologic Scaffold Materials Through Physicomechanical, Thermal, and Enzymatic Degradation Techniques. https://app.cochat.ai/papers/10.1097/sla.0b013e3182445341
The paper
Deeken, C. R., Eliason, B. J., Pichert, M. D., Grant, S. A., Frisella, M. M., & Matthews, B. D. (2012). Differentiation of Biologic Scaffold Materials Through Physicomechanical, Thermal, and Enzymatic Degradation Techniques. Annals of Surgery. https://doi.org/10.1097/sla.0b013e3182445341

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.