Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Value of Transient Elastography Measured With Fibroscan in Predicting the Outcome of Hepatic Resection for Hepatocellular Carcinoma

Open access
Cescon, Matteo, Colecchia, Antonio, Cucchetti, Alessandro, Peri, Eugenia, Montrone, Luciana, Ercolani, Giorgio, Festi, Davide, Pinna, Antonio Daniele · 2012 · Annals of Surgery

Abstract

OBJECTIVE: : To evaluate the efficacy of preoperative liver stiffness (LS) measurement in predicting postoperative liver failure (PLF) after hepatectomy for hepatocellular carcinoma (HCC). BACKGROUND: : Hepatectomy for HCC in cirrhosis is affected by the risk of PLF, which is not completely predictable with common biochemical tests. Transient elastography with FibroScan is used to calculate the degree of LS, and it may be applicable to patients scheduled for hepatectomy to estimate perioperative complications. METHODS: : Ninety-two patients undergoing hepatectomy for HCC were prospectively evaluated with preoperative FibroScan. Accuracy of LS measurement in predicting PLF, the presence of cirrhosis, and the presence of clinical signs of portal hypertension (PH) were assessed using receiver operating characteristic (ROC) analysis. RESULTS: : In 2 patients, LS measurement could not be performed because of obesity; consequently, 90 patients were suitable for the study. Perioperative mortality was 2.2% (2 patients); PLF occurred in 28.9% of patients (26 patients). ROC analysis identified patients with LS value higher than or equal to 15.7 kPa as being at higher risk of PLF [area under the curve (AUC) = 0.865, 95% confidence interval: 0.776-0.928; sensitivity = 96.1%; specificity = 68.7%; positive predictive value = 55.6%; negative predictive value = 97.8%; positive likelihood ratio = 3.08; negative likelihood ratio = 0.056; P < 0.001]. Patients with LS value lower than 14.8 kPa had no PLF. LS value higher than 12.6 kPa and higher than 19.6 kPa was correlated with the presence of cirrhosis (AUC = 0.880; P < 0.001), and of PH (AUC = 0.786; P < 0.001), respectively. Multivariate analysis showed that low preoperative serum sodium levels (P = 0.012), histological cirrhosis (P = 0.024), and elevated LS (P = 0.005) were independent predictors of PLF. CONCLUSIONS: : LS measured with FibroScan is a valid tool for prediction of PLF in patients undergoing hepatectomy for HCC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/sla.0b013e3182724ce8

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 173

Metadata

Authors
Cescon, M., Colecchia, A., Cucchetti, A., Peri, E., Montrone, L., Ercolani, G., Festi, D., & Pinna, A. D.
Venue
Annals of Surgery
Published
2012-11
Volume
256
Issue
5
Pages
706-713
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2328641507
Cited by
173
References
2
FWCI
5.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Value of Transient Elastography Measured With Fibroscan in Predicting the Outcome of Hepatic Resection for Hepatocellular Carcinoma. https://app.cochat.ai/papers/10.1097/sla.0b013e3182724ce8
The paper
Cescon, M., Colecchia, A., Cucchetti, A., Peri, E., Montrone, L., Ercolani, G., Festi, D., & Pinna, A. D. (2012). Value of Transient Elastography Measured With Fibroscan in Predicting the Outcome of Hepatic Resection for Hepatocellular Carcinoma. Annals of Surgery. https://doi.org/10.1097/sla.0b013e3182724ce8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.