The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
A Randomized Controlled Pilot Trial of Modified Whole Blood versus Component Therapy in Severely Injured Patients Requiring Large Volume Transfusions
Abstract
In Brief Objectives: To determine whether resuscitation of severely injured patients with modified whole blood (mWB) resulted in fewer overall transfusions compared with component (COMP) therapy. Background: For decades, whole blood (WB) was the primary product for resuscitating patients in hemorrhagic shock. After dramatic advances in blood banking in the 1970s, blood donor centers began supplying hospitals with individual components [red blood cell (RBC), plasma, platelets] and removed WB as an available product. However, no studies of efficacy or hemostatic potential in trauma patients were performed before doing so. Methods: Single-center, randomized trial of severely injured patients predicted to large transfusion volume. Pregnant patients, prisoners, those younger than 18 years or with more than 20% total body surface area burns (TBSA) burns were excluded. Patients were randomized to mWB (1 U mWB) or COMP therapy (1 U RBC+ 1 U plasma) immediately on arrival. Each group also received 1 U platelets (apheresis or prepooled random donor) for every 6 U of mWB or 6 U of RBC + 6 U plasma. The study was performed under the Exception From Informed Consent (Food and Drug Administration 21 code of federal regulations [CFR] 50.24). Primary outcome was 24-hour transfusion volumes. Results: A total of 107 patients were randomized (55 mWB, 52 COMP therapy) over 14 months. There were no differences in demographics, arrival vitals or laboratory values, injury severity, or mechanism. Transfusions were similar between groups (intent-to-treat analysis). However, when excluding patients with severe brain injury (sensitivity analysis), WB group received less 24-hour RBC (median 3 vs 6, P = 0.02), plasma (4 vs 6, P = 0.02), platelets (0 vs 3, P = 0.09), and total products (11 vs 16, P = 0.02). Conclusions: Compared with COMP therapy, WB did not reduce transfusion volumes in severely injured patients predicted to receive massive transfusion. However, in the sensitivity analysis (patients without severe brain injuries), use of mWB significantly reduced transfusion volumes, achieving the prespecified endpoint of this initial pilot study. This randomized trial set out to determine whether early resuscitation of severely injured patients with modified whole blood would results in fewer overall transfusions compared with component therapy. A total of 107 subjects were randomized over a 14-month period. Although there were no differences in transfusions between study groups (intent-to-treat), when patients with severe brain injury were excluded, patients in the modified whole blood group received less blood products in the first 24 hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Damage Control Resuscitation: Directly Addressing the Early Coagulopathy of Trauma
Holcomb, J. B., Jenkins, D., Rhee, P., Johannigman, J., Mahoney, P., Mehta, S., Cox, E. D., Gehrke, M. J., Beilman, G. J., Schreiber, M., et al. (2007) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e3180324124 · Cited by 1,370
Self-citationManagement of the Major Coagulopathy with Onset during Laparotomy
STONE, H. H., STROM, P. R., & MULLINS, R. J. (1983) · Annals of Surgery · doi:10.1097/00000658-198305000-00005 · Cited by 688
Spinella, P. C., Perkins, J. G., Grathwohl, K. W., Beekley, A. C., & Holcomb, J. B. (2009) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e31819d85fb · Cited by 544
Self-citationTHE CELLULAR, METABOLIC, AND SYSTEMIC CONSEQUENCES OF AGGRESSIVE FLUID RESUSCITATION STRATEGIES
Cotton, B. A., Guy, J. S., Morris, J. A., & Abumrad, N. N. (2006) · Shock · doi:10.1097/01.shk.0000209564.84822.f2 · Cited by 517
Self-citationPostinjury Multiple Organ Failure: A Bimodal Phenomenon
Moore, F. A., Sauaia, A., Moore, E. E., Haenel, J. B., Burch, J. M., & Lezotte, D. C. (1996) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199604000-00001 · Cited by 491
United States Army Rangers in Somalia: An Analysis of Combat Casualties on an Urban Battlefield
Mabry, R. L., Holcomb, J. B., Baker, A. M., Cloonan, C. C., Uhorchak, J. M., Perkins, D. E., Canfield, A. J., & Hagmann, J. H. (2000) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200009000-00021 · Cited by 479
Self-citationCotton, B. A., Gunter, O. L., Isbell, J., Au, B. K., Robertson, A. M., Morris, J. A., St. Jacques, P., & Young, P. P. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e31816c5c80 · Cited by 423
Self-citationHemostasis in Massively Transfused Trauma Patients
COUNTS, R. B., HAISCH, C., SIMON, T. L., MAXWELL, N. G., HEIMBACH, D. M., & CARRICO, C. J. (1979) · Annals of Surgery · doi:10.1097/00000658-197907000-00020 · Cited by 390
Definitions for sepsis and organ failure
Bone, R. C. (1992) · Critical Care Medicine · doi:10.1097/00003246-199206000-00002 · Cited by 360
Metadata
- Authors
- Cotton, B. A., Podbielski, J., Camp, E., Welch, T., del Junco, D., Bai, Y., Hobbs, R., Scroggins, J., Hartwell, B., Kozar, R. A., Wade, C. E., & Holcomb, J. B.
- Venue
- Annals of Surgery
- Published
- 2013-10
- Volume
- 258
- Issue
- 4
- Pages
- 527-533
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2324226739
- Cited by
- 292
- References
- 16
- FWCI
- 11.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Randomized Controlled Pilot Trial of Modified Whole Blood versus Component Therapy in Severely Injured Patients Requiring Large Volume Transfusions. https://app.cochat.ai/papers/10.1097/sla.0b013e3182a4ffa0
- The paper
- Cotton, B. A., Podbielski, J., Camp, E., Welch, T., del Junco, D., Bai, Y., Hobbs, R., Scroggins, J., Hartwell, B., Kozar, R. A., Wade, C. E., & Holcomb, J. B. (2013). A Randomized Controlled Pilot Trial of Modified Whole Blood versus Component Therapy in Severely Injured Patients Requiring Large Volume Transfusions. Annals of Surgery. https://doi.org/10.1097/sla.0b013e3182a4ffa0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.