Cited by 22Pelvic floor disorders treatmentsPhysical Activity and HealthLower Extremity Biomechanics and Pathologies

The relationship between intra-abdominal pressure and body acceleration during exercise.

Open access
de Gennaro, Johanna Day, de Gennaro, Claire K., Shaw, Janet M., Petelenz, Tomasz J., Nygaard, Ingrid E., Hitchcock, Robert W.·2019·Female Pelvic Medicine & Reconstructive Surgery

Abstract

Objectives: High intra-abdominal pressure (IAP) may influence the development of pelvic floor disorders. We and others have used intravaginal pressure transducers to measure IAP in women during exercise and daily activities, but utilizing the transducer for long-term measurements creates compliance issues. Waist-worn accelerometers are prominent in research and may be a reliable alternative for approximating IAP. We hypothesized that there are pair-wise positive correlations between the mean maximal accelerometer vector magnitude and 2 IAP measurements: mean maximal IAP and area under the curve (AUC). Methods: Twenty-five women who regularly participated in exercise performed 13 activities. Intra-abdominal pressure was measured with an intravaginal transducer and acceleration with a waist-worn accelerometer. We determined the mean maximal IAP, AUC for IAP, and mean maximal accelerometer vector magnitude for each activity and participant. The relationship between IAP and acceleration was determined by computing the Pearson correlation coefficient (R) and the 95% confidence interval for mean maximal accelerometer vector magnitude versus mean maximal IAP and mean maximal accelerometer vector magnitude versus AUC for IAP. Results: The R values were 0.7353 for mean maximal accelerometer vector magnitude versus mean maximal IAP (including walking) and 0.5059 for mean maximal accelerometer vector magnitude versus AUC for IAP (excluding walking). Walking at 3 speeds, analyzed separately, presented R values of 0.72208 for mean maximal IAP and 0.21678 for AUC. Conclusion: Waist-worn accelerometers may provide a viable method for approximating mean maximal IAP in a population of women during most activities.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/spv.0000000000000523

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Accelerometers were used as a proxy to estimate mean IAP and have previously demonstrated good correlation with mean maximal IAP with a variety of activities.

    “Finally, accelerometers were used as a proxy to estimate mean IAP and have previously demonstrated good correlation with mean maximal IAP with a variety of activities.”

    From Standard Restrictions vs Expedited Activity After Pelvic Organ Prolapse Surgery (2023) · cites this paper as [28]

    The Discussion reports a strong correlation (0.7353) between mean maximal accelerometer vector magnitude and mean maximal IAP across activities, supporting the correlation claim. It says accelerometry may approximate maximal IAP, but does not establish it as a proxy for mean IAP generally; it also identifies static exercises with high abdominal muscle recruitment as exceptions. (LLM, conf=0.83)

    Experimental — accuracy not yet measured
  • There are limitations to the information that the accelerometer may provide during static exercises that generate minimal accelerometer movement.

    “However, there are limitations to the information that the accelerometer may provide during static exercises that generate minimal accelerometer movement.28”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. [17]Brown JHU Physiology of Man in Space New York, NY Academic Press Inc 1963
  2. [19]Pescatello LS Arena R Riebe D ACSM’s Guidelines for Exercise Testing and Prescription 9 2014 Philadelphia, PA Lippincott Williams & Wilkins 23851406
  3. [23]Hulley SB Cummings SR Browner WS Designing clinical research: an epidemiologic approach 4 Philadelphia, PA Lippincott Williams & Wilkins 2013

Cited by

Sorted by citations

Authors
de Gennaro, J. D., de Gennaro, C. K., Shaw, J. M., Petelenz, T. J., Nygaard, I. E., & Hitchcock, R. W.
Affiliations
  • Department of Bioengineering,
  • School of Medicine,
  • Department of Health, Kinesiology, and Recreation, and
  • University of Utah (US)
Corresponding author
  • Petelenz, Tomasz J.
  • Hitchcock, Robert W.
Venue
Female Pelvic Medicine & Reconstructive Surgery
Published
2019-05
Volume
25
Issue
3
Pages
231-237
ISSN
2151-8378 (ISSN-L)
OpenAlex
W2770028135
Cited by
22
References
28
Citations by year
2026: 3 · 2025: 5 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 1 · 2020: 5 · 2019: 1
FWCI
1.43
Type
journal article
Language
en
Open access
Locations
  • Urogynecology (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (P01HD080629)
Topics
  • Health Sciences › Medicine › Rheumatology › Pelvic floor disorders treatments
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
intra-abdominal pressure, waist-worn accelerometers, pelvic floor dysfunction, physical activity, area under the curve, walking, women
MeSH terms
Acceleration, Adolescent, Adult, Female, Humans, Middle Aged, Pressure, Exercise, Walking, Monitoring, Ambulatory, Abdominal Cavity, Young Adult, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review