Evaluation of the safety and feasibility of resuscitative endovascular balloon occlusion of the aorta
The DOI matches its Crossref record.
Abstract
BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is one of the ultimately invasive procedures for managing a noncompressive torso injury. Since it is less invasive than resuscitative open aortic cross-clamping, its clinical application is expected. METHODS: We retrospectively evaluated the safety and clinical feasibility of REBOA (intra-aortic occlusion balloon, MERA, Tokyo, Japan) using the Seldinger technique to control severe hemorrhage. Of 5,230 patients admitted to our trauma center in Japan from 2007 to 2013, we included 24 who underwent REBOA primarily. The indications for REBOA were a pelvic ring fracture or hemoperitoneum with hemodynamically instability and impending cardiac arrest. Emergency hemostasis was performed during REBOA in all patients. RESULTS: All 24 patients had a blunt injury, the median age was 59 (interquartile range, 41-71 years), the median Injury Severity Score (ISS) was 47 (interquartile range, 37-52), the 30-day survival rate was 29.2% (n = 7), and the median probability survival rate was 12.5%. Indications for REBOA were hemoperitoneum and pelvic ring fracture in 15 cases and overlap in 8 cases. In 10 cases of death, the balloon could not be deflated in 5 cases. In 19 cases in which the balloon was deflated, the median duration of aortic occlusion was shorter in survivors than in deaths (21 minutes vs. 35 minutes, p = 0.05). The mean systolic blood pressure was significantly increased by REBOA (from 53.1 [21] mm Hg to 98.0 [26.6] mm Hg, p < 0.01). There were three cases with complications (12.5%), one external iliac artery injury and two lower limb ischemias in which lower limb amputation was necessary in all cases. Acute kidney injury developed in all three cases, but failure was not persistent. CONCLUSION: REBOA seems to be feasible for trauma resuscitation and may improve survivorship. However, the serious complication of lower limb ischemia warrants more research on its safety. LEVEL OF EVIDENCE: Therapeutic/care management, level V.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Davidson, A. J., Russo, R. M., Reva, V. A., Brenner, M. L., Moore, L. J., Ball, C., Bulger, E., Fox, C. J., DuBose, J. J., Moore, E. E., et al. (2018) · Journal of Trauma and Acute Care Surgery · doi:10.1097/ta.0000000000001711 · Cited by 172
“Early experience in Japan and Russia reported multiple cases of lower-extremity amputation following REBOA access in the ipsilateral limb after using 10 Fr to 14 Fr arterial sheaths.(27,63) There is similar anecdotal evidence in the United States (Fig.”
BackgroundProphylactic abdominal aorta balloon occlusion during caesarean section: a retrospective case series
Wei, X., Zhang, J., Chu, Q., Du, Y., Xing, N., Xu, X., Zhou, Y., & Zhang, W. (2016) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2015.12.001 · Cited by 69
Metadata
- Authors
- Saito, N., Matsumoto, H., Yagi, T., Hara, Y., Hayashida, K., Motomura, T., Mashiko, K., Iida, H., Yokota, H., & Wagatsuma, Y.
- Venue
- Journal of Trauma and Acute Care Surgery
- Published
- 2015-05
- Volume
- 78
- Issue
- 5
- Pages
- 897-904
- ISSN
- 2163-0755 (ISSN-L)
- OpenAlex
- W2334806946
- Cited by
- 228
- References
- 0
- FWCI
- 27.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the safety and feasibility of resuscitative endovascular balloon occlusion of the aorta. https://app.cochat.ai/papers/10.1097/ta.0000000000000614
- The paper
- Saito, N., Matsumoto, H., Yagi, T., Hara, Y., Hayashida, K., Motomura, T., Mashiko, K., Iida, H., Yokota, H., & Wagatsuma, Y. (2015). Evaluation of the safety and feasibility of resuscitative endovascular balloon occlusion of the aorta. Journal of Trauma and Acute Care Surgery. https://doi.org/10.1097/ta.0000000000000614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.