The pitfalls of resuscitative endovascular balloon occlusion of the aorta: Risk factors and mitigation strategies
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Despite technological advancements, REBOA is associated with significant risks due to complications of vascular access and ischemia-reperfusion. The inherent morbidity and mortality of REBOA is often compounded by coexisting injury and hemorrhagic shock. Additionally, the potential for REBOA-related injuries is exaggerated due to the growing number of interventions being performed by providers who have limited experience in endovascular techniques, inadequate resources, minimal training in the technique, and who are performing this maneuver in emergency situations. In an effort to ultimately improve outcomes with REBOA, we sought to compile a list of complications that may be encountered during REBOA usage. To address the current knowledge gap, we assembled a list of anecdotal complications from high-volume REBOA users internationally. More importantly, through a consensus model, we identify contributory factors that may lead to complications and deliberate on how to recognize, mitigate, and manage such events. An understanding of the pitfalls of REBOA and strategies to mitigate their occurrence is of vital importance to optimize patient outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus methods: characteristics and guidelines for use
Fink, A., Kosecoff, J., Chassin, M., & Brook, R. H. (1984) · American Journal of Public Health · doi:10.2105/ajph.74.9.979 · Cited by 2,089 · cited 1×
“The process was similar to a nominal consensus model once the study group was presented with a collated manuscript, yet it preserved the anonymity of a Delphi model for the initial round of complication solicitations.(12) The technique of REBOA has been broken down into six specific steps.”
ResultThe Pathophysiology of Aortic Cross-clamping and Unclamping
Gelman, S. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00027 · Cited by 603 · cited 2×
“On the other hand, Zone 3 occlusion may have a longer tolerable occlusion time, but does not control any hemorrhage above this level, and provides less support to myocardial and cerebral perfusion.(29) Malposition of the balloon can be even more catastrophic.”
BackgroundUse of an intra-aortic balloon catheter tamponade for controlling intra-abdominal hemorrhage in man.
Hughes, C. W. (1954) · PubMed · Cited by 348
Moore, L. J., Brenner, M., Kozar, R. A., Pasley, J., Wade, C. E., Baraniuk, M. S., Scalea, T., & Holcomb, J. B. (2015) · Journal of Trauma and Acute Care Surgery · doi:10.1097/ta.0000000000000809 · Cited by 320 · cited 1×
“In the past several years, REBOA has experienced a renaissance, with its implementation rapidly expanding worldwide.(7)”
BackgroundSelf-citationSaito, N., Matsumoto, H., Yagi, T., Hara, Y., Hayashida, K., Motomura, T., Mashiko, K., Iida, H., Yokota, H., & Wagatsuma, Y. (2015) · Journal of Trauma and Acute Care Surgery · doi:10.1097/ta.0000000000000614 · Cited by 228 · cited 2×
“Early experience in Japan and Russia reported multiple cases of lower-extremity amputation following REBOA access in the ipsilateral limb after using 10 Fr to 14 Fr arterial sheaths.(27,63) There is similar anecdotal evidence in the United States (Fig.”
BackgroundNorii, T., Crandall, C., & Terasaka, Y. (2015) · Journal of Trauma and Acute Care Surgery · doi:10.1097/ta.0000000000000578 · Cited by 214 · cited 1×
“Early experience in Japan and Russia reported multiple cases of lower-extremity amputation following REBOA access in the ipsilateral limb after using 10 Fr to 14 Fr arterial sheaths.(27,63) There is similar anecdotal evidence in the United States (Fig.”
BackgroundInoue, J., Shiraishi, A., Yoshiyuki, A., Haruta, K., Matsui, H., & Otomo, Y. (2016) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000000968 · Cited by 147 · cited 1×
“Redistribution of circulating blood volume during balloon occlusion may exacerbate injuries proximal to the balloon because of dramatic increases in blood pressure and flow, destabilizing clot and resulting in increasing hemorrhage.(43,44) It is the opinion of most of the authors that any signs of proximal great vesse…”
BackgroundHörer, T. M., Skoog, P., Nilsson, K. F., OIKONOMAKIS, I. N., Larzon, T., Norgren, L., & Jansson, K. (2014) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2014.01.005 · Cited by 25 · cited 1×
“The cessation of distal blood flow results in distal organ ischemia, vasodilation, and a buildup of toxic metabolites.(46,50,51) Therefore, once the balloon is inflated, a plan should be quickly developed and enacted in order to achieve hemorrhage control.”
BackgroundC3 Modulates RBC Antigen to Negatively Regulate Antibody Response
Mener, A., Arthur, C. M., Patel, S. R., & Stowell, S. R. (2016) · Blood · doi:10.1182/blood.v128.22.22.22 · Cited by 23
Metadata
- Authors
- Davidson, A. J., Russo, R. M., Reva, V. A., Brenner, M. L., Moore, L. J., Ball, C., Bulger, E., Fox, C. J., DuBose, J. J., Moore, E. E., & Rasmussen, T. E.
- Venue
- Journal of Trauma and Acute Care Surgery
- Published
- 2018-01
- Volume
- 84
- Issue
- 1
- Pages
- 192-202
- ISSN
- 2163-0755 (ISSN-L)
- 2163-0763
- OpenAlex
- W2762444358
- Cited by
- 172
- References
- 9
- FWCI
- 17.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The pitfalls of resuscitative endovascular balloon occlusion of the aorta: Risk factors and mitigation strategies. https://app.cochat.ai/papers/10.1097/ta.0000000000001711
- The paper
- Davidson, A. J., Russo, R. M., Reva, V. A., Brenner, M. L., Moore, L. J., Ball, C., Bulger, E., Fox, C. J., DuBose, J. J., Moore, E. E., & Rasmussen, T. E. (2018). The pitfalls of resuscitative endovascular balloon occlusion of the aorta: Risk factors and mitigation strategies. Journal of Trauma and Acute Care Surgery. https://doi.org/10.1097/ta.0000000000001711
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.