The DOI matches its Crossref record.
QuikClot Use in Trauma for Hemorrhage Control: Case Series of 103 Documented Uses
Abstract
BACKGROUND: Local hemostatics have recently been introduced for field use to control external hemorrhage. The objective of this report is to describe the initial clinical experience with QuikClot, a zeolite that works by absorbing water and concentrating coagulation factors to stop bleeding in a series of patients. METHODS: Documented cases using a self-reporting survey sheet submitted by the users and first-hand detailed interviews with the users when possible. RESULTS: There were 103 documented cases of QuikClot use: 69 by the US military in Iraq, 20 by civilian trauma surgeons and 14 by civilian first responders. There were 83 cases involving application to external wounds and 20 cases of intracorporeal use by military and civilian surgeons. All field applications by first responders were successful in controlling hemorrhage. The overall efficacy rate was 92% with eight cases of ineffectiveness noted by physicians in morbid patients with massive injuries when the QuikClot was used as a last resort. These reported failures were thought to be a result of the coagulopathic state of the patient from massive resuscitation or the inability to get the product directly to the source of hemorrhage. When the QuikClot was applied on responsive patients, the heat generated by the exothermic reaction caused mild to severe pain and discomfort. There were three cases of burns caused by the heat generated by the QuikClot application with one case requiring skin grafting. There was one major complication from intracorporeal use caused by scar formation from a foreign body reaction. CONCLUSIONS: QuikClot has been effectively used by a wide range of providers in the field and hospital to control hemorrhage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development of a chitosan-based wound dressing with improved hemostatic and antimicrobial properties
Ong, S.-Y., Wu, J., Moochhala, S. M., Tan, M.-H., & Lu, J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.034 · Cited by 830
Biomaterials and Advanced Technologies for Hemostatic Management of Bleeding
Hickman, D. A., Pawlowski, C. L., Sekhon, U. D. S., Marks, J., & Gupta, A. S. (2018) · Advanced Materials · doi:10.1002/adma.201700859 · Cited by 583
Bioactive glasses beyond bone and teeth: Emerging applications in contact with soft tissues
Miguez-Pacheco, V., Hench, L. L., & Boccaccini, A. R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.004 · Cited by 544
A Comprehensive Review of Topical Hemostatic Agents: Efficacy and Recommendations for Use
Achneck, H. E., Sileshi, B., Jamiolkowski, R. M., Albala, D. M., Shapiro, M. L., & Lawson, J. H. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181c3bcca · Cited by 481
Trends in 1029 trauma deaths at a level 1 trauma center: Impact of a bleeding control bundle of care
Oyeniyi, B. T., Fox, E. E., Scerbo, M., Tomasek, J. S., Wade, C. E., & Holcomb, J. B. (2017) · Injury · doi:10.1016/j.injury.2016.10.037 · Cited by 296
Metadata
- Authors
- Rhee, P., Brown, C., Martin, M., Salim, A., Plurad, D., Green, D., Chambers, L., Demetriades, D., Velmahos, G., & Alam, H.
- Venue
- Journal of Trauma: Injury, Infection & Critical Care
- Published
- 2008-04
- Volume
- 64
- Issue
- 4
- Pages
- 1093-1099
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W2077441972
- Cited by
- 224
- References
- 0
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: QuikClot Use in Trauma for Hemorrhage Control: Case Series of 103 Documented Uses. https://app.cochat.ai/papers/10.1097/ta.0b013e31812f6dbc
- The paper
- Rhee, P., Brown, C., Martin, M., Salim, A., Plurad, D., Green, D., Chambers, L., Demetriades, D., Velmahos, G., & Alam, H. (2008). QuikClot Use in Trauma for Hemorrhage Control: Case Series of 103 Documented Uses. Journal of Trauma: Injury, Infection & Critical Care. https://doi.org/10.1097/ta.0b013e31812f6dbc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.