CoChat

Effect of video laryngoscopy on trauma patient survival: A randomized controlled trial

Yeatts, Dale J., Dutton, Richard P., Hu, Peter F., Chang, Yu-Wei W., Brown, Clayton H., Chen, Hegang, Grissom, Thomas E., Kufera, Joseph A., Scalea, Thomas M. · 2013 · Journal of Trauma and Acute Care Surgery
Cited by 122

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Many resuscitation scenarios include the use of emergency intubation to support injured patients. New video-guided airway management technology is available, which may minimize the risk to patients from this procedure. METHODS: This was a controlled clinical trial conducted in the trauma receiving unit in a university-affiliated urban hospital in which 623 consecutive adult patients requiring emergency airway management were prospectively randomized to intubation with either the direct laryngoscope (DL) or the GlideScope video laryngoscope (GVL) device. RESULTS: The primary outcome was survival to hospital discharge. There was no significant difference in mortality between the GVL group (28 [9%] of 303) and the DL group (24 [8%] of 320) (p = 0.43) for all patients. Within a smaller cohort identified retrospectively, there was a higher mortality rate seen in the subgroup of patients with severe head injuries (head Abbreviated Injury Scale [AIS] score > 3) who were randomized to intubation with GVL (22 [30%] of 73) versus DL (16 [14%] of 112) (p = 0.047). Among all patients, median intubation duration in seconds was significantly higher for the GVL group (median, 56; interquartile range, 40-81) than for the DL group (median, 40; interquartile range, 24-68) (p < 0.001). Among those with severe head injuries, median intubation duration in seconds was also significantly higher for the GVL group (median, 74) than for the DL group (median, 65) (p < 0.003). Correspondingly, this group also experienced a greater incidence of low oxygen saturations of 80% or less (27 [50%] of 54 for the GVL group and 15 [24%] of 63 for the DL group; p = 0.004). There were no significant differences between the two groups in first-pass success (80% for GVL and 81% for DL, p = 0.46). CONCLUSION: Use of the GlideScope did not influence survival to hospital discharge among all patients and was associated with longer intubation times than direct laryngoscopy. Among the video laryngoscope cohort, a smaller subgroup of severe head injury trauma patients identified retrospectively seemed to be associated with a greater incidence of hypoxia of 80% or less and mortality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ta.0b013e318293103d

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 122

Metadata

Authors
Yeatts, D. J., Dutton, R. P., Hu, P. F., Chang, Y.-W. W., Brown, C. H., Chen, H., Grissom, T. E., Kufera, J. A., & Scalea, T. M.
Venue
Journal of Trauma and Acute Care Surgery
Published
2013-08
Volume
75
Issue
2
Pages
212-219
ISSN
2163-0755 (ISSN-L)
OpenAlex
W1976353818
Cited by
122
References
2
FWCI
14.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.