Perioperative supplemental oxygen to reduce surgical site infection after open fixation of high-risk fractures: A randomized controlled pilot trial
The DOI matches its Crossref record.
Abstract
BACKGROUND: Higher concentrations of fraction of inspired oxygen (FIO2) have been shown to be associated with lower risk for surgical site infection in multiple studies outside the domain of orthopedic surgery. We evaluated the efficacy of high FIO2 administered during the perioperative period to reduce the rate of surgical site infection after open fixation of lower-extremity fractures at high risk of infection. METHODS: We conducted a randomized controlled, parallel design, double-blind study. Patients sustaining high-energy tibial plateau, tibial pilon, and calcaneus fractures treated in a staged fashion were selected for enrollment because these injuries are associated with high risk of infection. The study population included 222 patients with 235 fractures. Consenting patients were randomized by random number sequence to either the treatment or the control group. Treatment group patients received 80% FIO2 intraoperatively and for 2 hours afterward. Control group patients received 30% FIO2 during the same period. Surgeons, patients, and personnel who performed wound assessments were blinded to group assignment. The primary outcome measure was surgical site infection as defined by the Centers for Disease Control criteria for postoperative wound infection. RESULTS: The overall rates of postoperative surgical site infection were 12% (14 of 119 fractures) in the treatment group and 16% (19 of 116 fractures) in the control group (p = 0.31). Multivariate analysis, accounting for risk factors for infection, yielded the closest to a statistically significant reduction in the odds of infection with treatment (odds ratio, 0.54; p = 0.17). No treatment-associated events were observed. CONCLUSION: Use of a high concentration of FIO2 during the perioperative period is safe and shows a trend toward reduction of surgical site infection in patients undergoing open operative fixation of high-energy traumatic lower-extremity fractures. Further study in a larger patient population is indicated. LEVEL OF EVIDENCE: Therapeutic study, level III.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Allegranzi, B., Zayed, B., Bischoff, P., Kubilay, N. Z., de Jonge, S., de Vries, F., Gomes, S. M., Gans, S., Wallert, E. D., Wu, X., et al. (2016) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(16)30402-9 · Cited by 867
Chu, D. K., Kim, L. H.-Y., Young, P. J., Zamiri, N., Almenawer, S. A., Jaeschke, R., Szczeklik, W., Schünemann, H. J., Neary, J. D., & Alhazzani, W. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30479-3 · Cited by 778
Evidence for compromised data integrity in studies of liberal peri‐operative inspired oxygen
Myles, P. S., Carlisle, J. B., & Scarr, B. (2019) · Anaesthesia · doi:10.1111/anae.14584 · Cited by 64
Effect of intraoperative hyperoxia on the incidence of surgical site infections: a meta-analysis
Cohen, B., Schacham, Y. N., Ruetzler, K., Ahuja, S., Yang, D., Mascha, E. J., Barclay, A. B., Hung, M. H., & Sessler, D. I. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.02.027 · Cited by 59
Supplemental oxygen and surgical site infection: getting to the truth
Myles, P. S., & Kurz, A. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex096 · Cited by 46
Crowley, P., Stuttgen, V., O'Carroll, E., Ash, S., Buggy, D., & Gallagher, H. (2017) · Medical Gas Research · doi:10.4103/2045-9912.222446 · Cited by 7
Metadata
- Authors
- Stall, A., Paryavi, E., Gupta, R., Zadnik, M., Hui, E., & O’Toole, R. V.
- Venue
- Journal of Trauma and Acute Care Surgery
- Published
- 2013-10
- Volume
- 75
- Issue
- 4
- Pages
- 657-663
- ISSN
- 2163-0755 (ISSN-L)
- OpenAlex
- W2081993814
- Cited by
- 65
- References
- 0
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.