Risk Factors for Human Corneal Graft Failure Within the Australian Corneal Graft Registry
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Our aims were to examine graft survival and visual outcome after full-thickness corneal transplantation. METHODS: Records of 18,686 penetrating corneal grafts, 14,622 with archival follow-up from 1 to 22 years, were examined within a national database. Kaplan-Meier survival analysis indicated variables of interest for Cox proportional hazards regression analysis. A model clustered by patient to control intereye or intergraft dependence was constructed to identify variables best predicting penetrating corneal graft failure. Visual acuity in the grafted eye was measured by Snellen acuity. RESULTS: Probability of corneal graft survival was 0.87, 0.73, 0.60, and 0.46 at 1, 5, 10, and 15 years, respectively. Reasons for graft failure included irreversible rejection (34%), corneal endothelial cell failure including cases of glaucoma (24%), and infection (14%). Variables predicting graft failure in multivariate analysis included transplant center, location and volume of surgeon's case-load, graft era, indication for graft, number of previous ipsilateral grafts, lens status, corneal neovascularization at transplantation, a history of ocular inflammation or raised intraocular pressure, graft diameter, and postoperative events including graft neovascularization and rejection. Best-corrected Snellen acuity of 6/12 or better was achieved by 45%, and of less than 6/60 by 26%, of grafted eyes at last follow-up. CONCLUSIONS: The short-term survival of penetrating corneal transplants is excellent, but the eventual attrition rate appears inexorable and many factors that influence graft survival significantly are not amenable to change. Most penetrating grafts are performed for visual improvement, and excellent acuity will be achieved by approximately half of all grafts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peto, R., Pike, M. C., Armitage, P., Breslow, N. E., Cox, D. R., Howard, S. V., Mantel, N., McPherson, K., Peto, J., & Smith, P. G. (1977) · British Journal of Cancer · doi:10.1038/bjc.1977.1 · Cited by 8,285
A Note on Robust Variance Estimation for Cluster‐Correlated Data
Williams, R. L. (2000) · Biometrics · doi:10.1111/j.0006-341x.2000.00645.x · Cited by 2,501 · cited 1×
“A model clustered by patient to control for intereye or intergraft dependence was constructed to identify variables best predicting penetrating corneal graft failure (7).”
MethodPeto, R., Pike, M. C., Armitage, P., Breslow, N. E., Cox, D. R., Howard, S. V., Mantel, N., McPherson, K., Peto, J., & Smith, P. G. (1976) · British Journal of Cancer · doi:10.1038/bjc.1976.220 · Cited by 2,294
Cited by
Tan, D. T., Dart, J. K., Holland, E. J., & Kinoshita, S. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60437-1 · Cited by 799
Wei, C., Wang, Y., Ma, L., Wang, X., Chi, H., Zhang, S., Liu, T., Li, Z., Xiang, D., Dong, Y., et al. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.02283 · Cited by 38
Metadata
- Authors
- Williams, K. A., Lowe, M., Bartlett, C., Kelly, T.-L., & Coster, D. J.
- Venue
- Transplantation
- Published
- 2008-12-27
- Volume
- 86
- Issue
- 12
- Pages
- 1720-1724
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2064413114
- Cited by
- 244
- References
- 3
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Risk Factors for Human Corneal Graft Failure Within the Australian Corneal Graft Registry. https://app.cochat.ai/papers/10.1097/tp.0b013e3181903b0a
- The paper
- Williams, K. A., Lowe, M., Bartlett, C., Kelly, T.-L., & Coster, D. J. (2008). Risk Factors for Human Corneal Graft Failure Within the Australian Corneal Graft Registry. Transplantation. https://doi.org/10.1097/tp.0b013e3181903b0a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.