Cited by 18Medical Coding and Health InformationGlaucoma and retinal disordersClinical Reasoning and Diagnostic Skills

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Validity of Administrative Coding for Nonarteritic Ischemic Optic Neuropathy

Open access
Hamedani, Ali G., Kim, Dale S., Chaitanuwong, Pareena, Gonzalez, Lizbeth A., Moss, Heather E., DeLott, Lindsey B.·2024·Journal of Neuro-Ophthalmology

Abstract

Background: Administrative claims have been used to study the incidence and outcomes of nonarteritic ischemic optic neuropathy (NAION), but the validity of International Classification of Diseases (ICD)-10 codes for identifying NAION has not been examined. Methods: We identified patients at 3 academic centers who received ≥1 ICD-10 code for NAION in 2018. We abstracted the final diagnosis from clinical documentation and recorded the number of visits with an NAION diagnosis code. We calculated positive predictive value (PPV) for the overall sample and stratified by subspecialty and the number of diagnosis codes. For patients with ophthalmology or neuro-ophthalmology visit data, we recorded presenting symptoms, examination findings, and laboratory data and calculated PPV relative to case definitions of NAION that incorporated sudden onset of symptoms, optic disc edema, afferent pupillary defect, and other characteristics. Results: Among 161 patients, PPV for ≥1 ICD-10 code was 74.5% (95% CI: 67.2%–80.7%). PPV was similar when restricted to patients who had visited an ophthalmologist (75.8%, 95% CI: 68.4%–82.0%) but increased to 86.8% when restricted to those who had visited neuro-ophthalmologists (95% CI: 79.2%–91.9%). Of 113 patients with >1 ICD-10 code and complete examination data, 37 (32.7%) had documented sudden onset, optic disc swelling, and an afferent pupillary defect (95% CI: 24.7%–42.0%). Of the 76 patients who did not meet these criteria, 54 (71.0%) still received a final clinical diagnosis of NAION; for most (41/54, 75.9%), this discrepancy was due to lack of documented optic disc edema. Conclusions: The validity of ICD-10 codes for NAION in administrative claims data is high, particularly when combined with provider specialty.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/wno.0000000000002163

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Show all 1 references

Research works printed but not linked: 15

  1. Hattenhauer, 1997, Incidence of nonarteritic anterior ischemic optic neuropathy, Am J Ophthalmol., 123, 103, 10.1016/S0002-9394(14)70999-7 · DOI · Paper page
  2. Rubin, 2017, Ischemic optic neuropathy in cardiac surgery: incidence and risk factors in the United States from the national inpatient sample 1998 to 2013, Anesthesiology, 126, 810, 10.1097/ALN.0000000000001533 · DOI
  3. Rubin, 2016, Perioperative visual loss in spine fusion surgery: ischemic optic neuropathy in the United States from 1998 to 2012 in the nationwide inpatient sample, Anesthesiology, 125, 457, 10.1097/ALN.0000000000001211 · DOI
  4. Lee, 2011, Incidence of nonarteritic anterior ischemic optic neuropathy: increased risk among diabetic patients, Ophthalmology, 118, 959, 10.1016/j.ophtha.2011.01.054 · DOI · Paper page
  5. Lee, 2016, Increased risk of stroke in patients with nonarteritic anterior ischemic optic neuropathy: a nationwide retrospective cohort study, Am J Ophthalmol., 170, 183, 10.1016/j.ajo.2016.08.006 · DOI
  6. Hamedani, 2020, Validity of International Classification of Diseases codes for identifying neuro-ophthalmic disease in large data sets: a systematic review, J Neuroophthalmol., 40, 514, 10.1097/WNO.0000000000000971 · DOI · Paper page
  7. Khushzad, 2021, Predictive value of International Classification of Diseases codes for idiopathic intracranial hypertension in a university health system, J Neuroophthalmol., 41, e679, 10.1097/WNO.0000000000000992 · DOI
  8. Muro-Fuentes, 2021, Factors associated with increased emergency department utilization in patients with acute optic neuritis, J Neuroophthalmol., 41, 335, 10.1097/WNO.0000000000001294 · DOI
  9. Muro-Fuentes, 2023, Accuracy of International Classification of Diseases codes for identifying acute optic neuritis, J Neuroophthalmol., 43, 317, 10.1097/WNO.0000000000001805 · DOI
  10. Borkar, 2019, Techniques for improving ophthalmic studies performed on administrative databases, Ophthalmic Epidemiol., 26, 147, 10.1080/09286586.2018.1554160 · DOI
  11. Stein, 2013, Identification of persons with incident ocular diseases using health care claims databases, Am J Ophthalmol., 156, 1169, 10.1016/j.ajo.2013.06.035 · DOI
  12. Feng, 2023, A validated method to identify neuro-ophthalmologists in a large administrative claims database, J Neuroophthalmol., 43, 153, 10.1097/WNO.0000000000001794 · DOI
  13. Xue, 2023, Sociodemographic and geographic variation in access to neuro-ophthalmologists in the United States, J Neuroophthalmol., 43, 149, 10.1097/WNO.0000000000001821 · DOI
  14. Wang, 2021, Case contamination in electronic health records based case-control studies, Biometrics, 77, 67, 10.1111/biom.13264 · DOI
  15. 1995, Optic nerve decompression surgery for nonarteritic anterior ischemic optic neuropathy (NAION) is not effective and may be harmful. The Ischemic Optic Neuropathy Decompression Trial Research Group, JAMA, 273, 625, 10.1001/jama.1995.03520320035038 · DOI · Paper page

Cited by

Sorted by citations

See all 18

Metadata

Authors
Hamedani, A. G., Kim, D. S., Chaitanuwong, P., Gonzalez, L. A., Moss, H. E., & DeLott, L. B.
Affiliations
  • Rajavithi Hospital (TH)
  • Ministry of Public Health (TH)
Corresponding author
Hamedani, Ali G.
Venue
Journal of Neuro-Ophthalmology
Published
2024-05-06
Volume
44
Issue
3
Pages
342-345
ISSN
1070-8022 (ISSN-L)
OpenAlex
W4396664258
Cited by
18
References
1
Citations by year
2026: 9 · 2025: 6 · 2024: 3
FWCI
5.50
Type
journal article
Language
en
Open access
Locations
  • Journal of Neuro-Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
Funders
  • National Eye Institute (P30 EY026877)
  • Research to Prevent Blindness (N/A)
Topics
  • Health Sciences › Health Professions › Health Information Management › Medical Coding and Health Information
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Family Practice › Clinical Reasoning and Diagnostic Skills
Keywords
nonarteritic anterior ischemic optic neuropathy, ICD-10 codes, administrative claims data, positive predictive value, optic disc edema, afferent pupillary defect, neuro-ophthalmology, case definition
MeSH terms
Aged, Female, Humans, Male, Middle Aged, Retrospective Studies, United States, Reproducibility of Results, Incidence, Optic Neuropathy, Ischemic, International Classification of Diseases, Clinical Coding

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review