Differentiation of Horner Syndrome and Physiological Anisocoria by Automated Pupillometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: The differentiation of Horner syndrome from physiological anisocoria is important yet clinically challenging. We investigated the diagnostic accuracy of pupillometry to discriminate Horner syndrome from physiological anisocoria compared to pharmacological testing with the alpha-2-agonist apraclonidine, which is considered the current gold standard. Methods: Forty-four adult patients, mostly referred to our neuro-ophthalmology service for evaluation of anisocoria, were included. Automated binocular pupillometry was performed under standardized light conditions before and >30 minutes after instillation of 1% apraclonidine eye drops. A positive apraclonidine test indicating unilateral Horner syndrome was defined as an increase of pupil size in the smaller pupil and decrease of size in the larger pupil. Receiver operator characteristic curves were calculated to find the best pupillometric parameter discriminating Horner syndrome from physiological anisocoria. Results: We found that the parameters measuring the pupillary dilation lag using pupillometry could reliably discriminate Horner syndrome from physiological anisocoria compared to pharmacological testing. Calculating the change of anisocoria at 3–4 seconds after light-off relative to the anisocoria at the end of the light-on period (Δ3-4) may be most suitable to rule out Horner syndrome reaching a sensitivity of 95% and specificity of 68% using a cutoff of 0.35 mm. Conclusions: Our results indicate that pupillometry is a robust tool to measure the dilation lag in Horner syndrome and, therefore, to distinguish pathological from physiological anisocoria obviating pharmacological testing. The high sensitivity of the test will allow to identify the patients with Horner syndrome requiring further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In particular, parameters obtained through digital pupillometry have been reported to provide higher specificity compared to conventional clinical tests in the diagnosis of Horner's syndrome (25).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [25]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ruling a diagnosis in or out with “SpPIn” and “SnNOut”: a note of caution
Pewsner, D., Battaglia, M., Minder, C., Marx, A., Bucher, H. C., & Egger, M. (2004) · BMJ · doi:10.1136/bmj.329.7459.209 · Cited by 196
Research works printed but not linked: 18
- 1969, Johann Friedrich Horner (1831–1886) “a form of ptosis.”, JAMA., 208, 1899, 10.1001/jama.1969.03160100089019 · doi:10.1001/jama.1969.03160100089019
- Sabbagh, 2020, Causes of Horner syndrome: a study of 318 patients, J Neuroophthalmol., 40, 362, 10.1097/WNO.0000000000000844 · doi:10.1097/wno.0000000000000844
- Steck, 2018, Physiologic anisocoria under various lighting conditions, Clin Ophthalmol., 12, 85, 10.2147/OPTH.S147019 · doi:10.2147/opth.s147019
- Ettinger, 1991, Anisocoria: variation and clinical observation with different conditions of illumination and accommodation, Invest Ophthalmol Vis Sci., 32, 501
- George, 2019, The prevalence of physiological anisocoria and its clinical significance—a neurosurgical perspective, Neurol India., 67, 1500, 10.4103/0028-3886.273623 · doi:10.4103/0028-3886.273623
- Wilhelm, 1992, Horner's syndrome: a retrospective analysis of 90 cases and recommendations for clinical handling, Ger J Ophthalmol., 1, 96
- Van der Wiel, 1986, The diagnosis of Horner's syndrome. Use and limitations of the cocaine test, J Neurol Sci., 73, 311, 10.1016/0022-510X(86)90155-3 · doi:10.1016/0022-510x(86)90155-3
- Garibaldi, 2006, Effect of 0.5% apraclonidine on ptosis in Horner syndrome, Ophthalmic Plast Reconstr Surg., 22, 53, 10.1097/01.iop.0000196322.05586.6a · doi:10.1097/01.iop.0000196322.05586.6a
- Morales, 2000, Ocular effects of apraclonidine in Horner syndrome, Arch Ophthalmol., 118, 951
- Bremner, 2019, Apraclonidine is better than cocaine for detection of Horner syndrome, Front Neurol., 10, 55, 10.3389/fneur.2019.00055 · doi:10.3389/fneur.2019.00055
- Kawasaki, 2008, False negative apraclonidine test in two patients with Horner syndrome, Klin Monbl Augenheilkd., 225, 520, 10.1055/s-2008-1027349 · doi:10.1055/s-2008-1027349
- Dewan, 2009, False-negative apraclonidine testing in acute Horner syndrome, Can J Ophthalmol., 44, 109, 10.3129/i08-162 · doi:10.3129/i08-162
- Cooper-Knock, 2011, Early diagnosis of Horner syndrome using topical apraclonidine, J Neuroophthalmol., 31, 214, 10.1097/WNO.0b013e31821a91fe · doi:10.1097/wno.0b013e31821a91fe
- Yoo, 2017, Efficacy of digital pupillometry for diagnosis of Horner syndrome, PLoS One., 12, e0178361, 10.1371/journal.pone.0178361 · DOI
- Omary, 2019, Buzzing sympathetic nerves: a new test to enhance anisocoria in Horner's syndrome, Front Neurol., 10, 107, 10.3389/fneur.2019.00107 · doi:10.3389/fneur.2019.00107
- Crippa, 2007, Pupillary dilation lag is intermittently present in patients with a stable oculosympathetic defect (Horner syndrome), Am J Ophthalmol., 143, 712, 10.1016/j.ajo.2006.10.049 · doi:10.1016/j.ajo.2006.10.049
- Cambron, 2011, Apraclonidine and my pupil, Clin Auton Res., 21, 347, 10.1007/s10286-011-0118-6 · doi:10.1007/s10286-011-0118-6
- Fierz, 2022, Apraclonidine—an eye opener, Front Ophthalmol., 2, 902821, 10.3389/fopht.2022.902821 · doi:10.3389/fopht.2022.902821
Cited by
Pupil and Pupillary Light Reflex
Özdağ, D., & Oztas, B. (2025) · Sakarya Üniversitesi Holistik Sağlık Dergisi · doi:10.54803/sauhsd.1767753 · Cited by 1
Metadata
- Authors
- Disse, L. R., Bockisch, C. J., Weber, K. P., & Fierz, F. C.
- Venue
- Journal of Neuro-Ophthalmology
- Published
- 2024-11-08
- Volume
- 45
- Issue
- 3
- Pages
- 327-332
- ISSN
- 1070-8022
- 1536-5166
- Cited by
- 4
- References
- 1
- Language
- en
- Funders
- Betty & David Koetser Foundation for Brain Research, Zurich, Switzerland
- Uniscientia Stiftung
- Faculty of Medicine, University of Zurich, Switzerland (Career Development Grant “Filling the Gap” 2020-2021)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differentiation of Horner Syndrome and Physiological Anisocoria by Automated Pupillometry. https://app.cochat.ai/papers/10.1097/wno.0000000000002262
- The paper
- Disse, L. R., Bockisch, C. J., Weber, K. P., & Fierz, F. C. (2025). Differentiation of Horner Syndrome and Physiological Anisocoria by Automated Pupillometry. Journal of Neuro-Ophthalmology. https://doi.org/10.1097/wno.0000000000002262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.