The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
American Clinical Neurophysiology Society Guideline 2: Guidelines for Standard Electrode Position Nomenclature
Abstract
Summary: This revision to the EEG Guidelines is an update incorporating current electroencephalography technology and practice and was previously published as Guideline 5. While the 10-10 system of electrode position nomenclature has been accepted internationally for almost two decades, it has not been used universally. The reasons for this and clinical scenarios when the 10-10 system provides additional localizing information are discussed in this revision. In addition, situations in which AF1/2, AF5/6, PO1/2 and PO5/6 electrode positions may be utilized for EEG recording are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
IFCN standards for digital recording of clinical EEG
Nuwer, M. R., Comi, G., Emerson, R., Fuglsang-Frederiksen, A., Guérit, J.-M., Hinrichs, H., Ikeda, A., Jose C. Luccas, F., & Rappelsburger, P. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00106-5 · Cited by 671
Age Terminology During the Perinatal Period
Committee on Fetus and Newborn (2004) · Pediatrics · doi:10.1542/peds.2004-1915 · Cited by 579
Guideline Thirteen: Guidelines for Standard Electrode Position Nomenclature
&NA; (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199401000-00014 · Cited by 556
Shellhaas, R. A., Chang, T., Tsuchida, T., Scher, M. S., Riviello, J. J., Abend, N. S., Nguyen, S., Wusthoff, C. J., & Clancy, R. R. (2011) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31823e96d7 · Cited by 502
Self-citationPhotic‐ and Pattern‐induced Seizures: A Review for the Epilepsy Foundation of America Working Group
Fisher, R. S., Harding, G., Erba, G., Barkley, G. L., & Wilkins, A. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.31405.x · Cited by 427
Electroencephalography in premature and full-term infants. Developmental features and glossary
André, M., Lamblin, M.-D., d’Allest, A. M., Curzi-Dascalova, L., Moussalli-Salefranque, F., Nguyen The Tich, S., Vecchierini-Blineau, M.-F., Wallois, F., Walls-Esquivel, E., & Plouin, P. (2010) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2010.02.002 · Cited by 346
Pretreatment EEG in childhood absence epilepsy
Dlugos, D., Shinnar, S., Cnaan, A., Hu, F., Moshé, S. L., Mizrahi, E. M., Masur, D. M., Sogawa, Y., Pichon, J. L., Levine, C., et al. (2013) · Neurology · doi:10.1212/wnl.0b013e31829a3373 · Cited by 81
Cited by
Emotions Recognition Using EEG Signals: A Survey
Alarcao, S. M., & Fonseca, M. J. (2019) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2714671 · Cited by 1,201
The standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Seizure detection using wearable sensors and machine learning: Setting a benchmark
Tang, J., El Atrache, R., Yu, S., Asif, U., Jackson, M., Roy, S., Mirmomeni, M., Cantley, S., Sheehan, T., Schubach, S., et al. (2021) · Epilepsia · doi:10.1111/epi.16967 · Cited by 146
Autonomic arousals contribute to brain fluid pulsations during sleep
Picchioni, D., Özbay, P. S., Mandelkow, H., de Zwart, J. A., Wang, Y., van Gelderen, P., & Duyn, J. H. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118888 · Cited by 104
Metadata
- Authors
- Acharya, J. N., Hani, A., Cheek, J., Thirumala, P., & Tsuchida, T. N.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2016-08
- Volume
- 33
- Issue
- 4
- Pages
- 308-311
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2491407016
- Cited by
- 278
- References
- 9
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: American Clinical Neurophysiology Society Guideline 2: Guidelines for Standard Electrode Position Nomenclature. https://app.cochat.ai/papers/10.1097/wnp.0000000000000316
- The paper
- Acharya, J. N., Hani, A., Cheek, J., Thirumala, P., & Tsuchida, T. N. (2016). American Clinical Neurophysiology Society Guideline 2: Guidelines for Standard Electrode Position Nomenclature. Journal of Clinical Neurophysiology. https://doi.org/10.1097/wnp.0000000000000316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.