Detecting Epileptic Seizures in Long-term Human EEG: A New Approach to Automatic Online and Real-Time Detection and Classification of Polymorphic Seizure Patterns
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Epileptic seizures can cause a variety of temporary changes in perception and behavior. In the human EEG they are reflected by multiple ictal patterns, where epileptic seizures typically become apparent as characteristic, usually rhythmic signals, often coinciding with or even preceding the earliest observable changes in behavior. Their detection at the earliest observable onset of ictal patterns in the EEG can, thus, be used to start more-detailed diagnostic procedures during seizures and to differentiate epileptic seizures from other conditions with seizure-like symptoms. Recently, warning and intervention systems triggered by the detection of ictal EEG patterns have attracted increasing interest. Since the workload involved in the detection of seizures by human experts is quite formidable, several attempts have been made to develop automatic seizure detection systems. So far, however, none of these found widespread application. Here, we present a novel procedure for generic, online, and real-time automatic detection of multimorphologic ictal-patterns in the human long-term EEG and its validation in continuous, routine clinical EEG recordings from 57 patients with a duration of approximately 43 hours and additional 1,360 hours of seizure-free EEG data for the estimation of the false alarm rates. We analyzed 91 seizures (37 focal, 54 secondarily generalized) representing the six most common ictal morphologies (alpha, beta, theta, and delta- rhythmic activity, amplitude depression, and polyspikes). We found that taking the seizure morphology into account plays a crucial role in increasing the detection performance of the system. Moreover, besides enabling a reliable (mean false alarm rate<0.5/h, for specific ictal morphologies<0.25/h), early and accurate detection (average correct detection rate>96%) within the first few seconds of ictal patterns in the EEG, this procedure facilitates the automatic categorization of the prevalent seizure morphologies without the necessity to adapt the proposed system to specific patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Kohonen, T. (2001) · Springer Series in Information Sciences · doi:10.1007/978-3-642-56927-2 · Cited by 16,019
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631 · cited 5×
“Here, we chose the Symlet 5 wavelets of scale 25 and 32 as CWT TABLE 1.”
MethodInfluentialAn Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
An introduction to kernel-based learning algorithms
Muller, K.-R., Mika, S., Ratsch, G., Tsuda, K., & Scholkopf, B. (2001) · IEEE Transactions on Neural Networks · doi:10.1109/72.914517 · Cited by 3,473 · cited 1×
“Therefore, in this study, we applied a more advanced classifier, SVM (e.g., Cristianini and Shawe-Taylor, 2000; Mueller et al., 2001; Schölkopf, 1998).”
MethodAutomatic recognition of epileptic seizures in the EEG
Gotman, J. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90038-4 · Cited by 674 · cited 1×
“The seminal work of Gotman (1982) first mentions the problem of polymorphic seizure types and the resulting difficulties for detection systems.”
BackgroundVesanto, J., Himberg, J., & Alhoniemi, E. J. (2000) · Cited by 611
Cited by
An automated system for epilepsy detection using EEG brain signals based on deep learning approach
Ullah, I., Hussain, M., Qazi, E.-U.-H., & Aboalsamh, H. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.04.021 · Cited by 622
Wavelet-based EEG processing for computer-aided seizure detection and epilepsy diagnosis
Faust, O., Acharya, U. R., Adeli, H., & Adeli, A. (2015) · Seizure · doi:10.1016/j.seizure.2015.01.012 · Cited by 572
Application of entropies for automated diagnosis of epilepsy using EEG signals: A review
Acharya, U. R., Fujita, H., Sudarshan, V. K., Bhat, S., & Koh, J. E. W. (2015) · Knowledge-Based Systems · doi:10.1016/j.knosys.2015.08.004 · Cited by 492
Hussein, R., Palangi, H., Ward, R. K., & Wang, Z. J. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.10.010 · Cited by 263
Weighted visibility graph with complex network features in the detection of epilepsy
Supriya, S., Siuly, S., Wang, H., Cao, J., & Zhang, Y. (2016) · IEEE Access · doi:10.1109/access.2016.2612242 · Cited by 216
Toward Drowsiness Detection Using Non-hair-Bearing EEG-Based Brain-Computer Interfaces
Wei, C.-S., Wang, Y.-T., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2790359 · Cited by 171
“The SVM classifier has been used in previous BCI applications for real-time EEG classification [35], [36].”
BackgroundMethodA machine learning system for automated whole-brain seizure detection
Fergus, P., Hussain, A., Hignett, D., Al-Jumeily, D., Abdel-Aziz, K., & Hamdan, H. (2016) · Applied Computing and Informatics · doi:10.1016/j.aci.2015.01.001 · Cited by 161
“Tele-EEG reporting has previously been suggested as a solution and more recently online systems [80], [81], which are interesting approaches, but carry increased costs and concerns over data security.”
Background
Metadata
- Authors
- Meier, R., Dittrich, H., Schulze-Bonhage, A., & Aertsen, A.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2008-06
- Volume
- 25
- Issue
- 3
- Pages
- 119-131
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2117504492
- Cited by
- 204
- References
- 29
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.