Enriched acoustic environment rescales auditory sensitivity
The DOI matches its Crossref record; 20 of the 22 references it cites were found in a registry or an index.
Abstract
Loudness perception may be controlled by a central gain, possibly dependent on the mean level of the acoustic environment. Owing to hearing loss, for instance, a decrease in sensory inputs could increase this central gain and cause an auditory hypersensitivity or hyperacusis. According to this model, individuals with hyperacusis, provided with an enriched acoustic environment specifically designed to compensate for the decrease in sensory inputs, should show an improvement in their hyperacusis. This study showed that such an enriched acoustic environment indeed decreased auditory hypersensitivity: stimuli initially considered as being too loud became comfortable after a few weeks of acoustic stimulation. Therefore, this original approach could provide a solution to the problem of hyperacusis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Two studies [39, 40] reported “acoustic training” for hyperacusis which notably improved symptoms in the long term, with symptoms remaining in remission over a year later.”
From Clinical Interventions for Hyperacusis in Adults: A Scoping Review to Assess the Current Position and Determine Priorities for Research (2017) · cites this paper as [39]
Citations
Cites
Noreña, A. J., & Eggermont, J. J. (2003) · Hearing Research · doi:10.1016/s0378-5955(03)00225-9 · Cited by 516 · cited 1×
“This is consistent with the decrease in central inhibition [21] and the increase in neural responses over a broad frequency range [17,18,22,23] induced by hearing loss.”
BackgroundSelf-citationPsychometric Normalization of a Hyperacusis Questionnaire
Khalfa, S., Dubal, S., Veuillet, E., Perez-Diaz, F., Jouvent, R., & Collet, L. (2002) · ORL · doi:10.1159/000067570 · Cited by 488 · cited 3×
“’s questionnaire [20] were also significantly decreased at s + 1m (average score: 26, Po0.”
BackgroundAuditory plasticity and hyperactivity following cochlear damage
Salvi, R. J., Wang, J., & Ding, D. (2000) · Hearing Research · doi:10.1016/s0378-5955(00)00136-2 · Cited by 437 · cited 1×
“This is consistent with the decrease in central inhibition [21] and the increase in neural responses over a broad frequency range [17,18,22,23] induced by hearing loss.”
BackgroundNorena, A., Micheyl, C., Chéry-Croze, S., & Collet, L. (2002) · Audiology and Neurotology · doi:10.1159/000066156 · Cited by 382
Self-citationFundamentals of Hearing: An Introduction: Fifth Edition
Yost, W. (2006) · BRILL eBooks · doi:10.1163/9789004501935 · Cited by 348
Noreña, A. J., & Eggermont, J. J. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2226-04.2005 · Cited by 337 · cited 2×
“Recently, a passive acoustic stimulation in the frequency range of noise-induced hearing loss has been shown to prevent the central changes usually induced after a noise trauma in cats [16,17].”
BackgroundSelf-citationHypersensitivity to sound: Questionnaire data, audiometry and classification
Anari, M., Axelsson, A., Eliasson, A., & Magnusson, L. (1999) · Scandinavian Audiology · doi:10.1080/010503999424653 · Cited by 271 · cited 3×
“In this context, hearing loss, which causes a decrease in sensory inputs to the central auditory system, could cause an abnormal increase in central gain and consequently an auditory hypersensitivity (most patients with hyperacusis present a hearing loss [6,11,14]).”
BackgroundGAD levels and muscimol binding in rat inferior colliculus following acoustic trauma
Milbrandt, J. C., Holder, T. M., Wilson, M. C., Salvi, R. J., & Caspary, D. M. (2000) · Hearing Research · doi:10.1016/s0378-5955(00)00135-0 · Cited by 198 · cited 2×
“This is consistent with the decrease in central inhibition [21] and the increase in neural responses over a broad frequency range [17,18,22,23] induced by hearing loss.”
BackgroundEnriched acoustic environment after noise trauma abolishes neural signs of tinnitus
Nore??a, A. J., & Eggermont, J. J. (2006) · NeuroReport · doi:10.1097/00001756-200604240-00001 · Cited by 190 · cited 3×
“Recently, a passive acoustic stimulation in the frequency range of noise-induced hearing loss has been shown to prevent the central changes usually induced after a noise trauma in cats [16,17].”
BackgroundAndersson, G., Lindvall, N., Hursti, T., Carlbring, P., & Andersson, G. (2002) · International Journal of Audiology · doi:10.3109/14992020209056075 · Cited by 189 · cited 1×
“The prevalence of hyperacusis is around 8% in the general population [7].”
BackgroundLoudness growth in 1/2-octave bands (LGOB)—A procedure for the assessment of loudness
Allen, J. B., Hall, J. L., & Jeng, P. S. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399778 · Cited by 182 · cited 10×
“The intensity step used in the LGOB test was then obtained by dividing the difference between the ‘too loud’ level and the absolute threshold by 14.”
BackgroundMethodInfluentialAssessment and amelioration of hyperacusis in tinnitus patients
Dauman, R., & Bouscau-Faure, F. (2005) · Acta Oto-Laryngologica · doi:10.1080/00016480510027565 · Cited by 179 · cited 5×
“Finally, chronic stimulation with broadband noise has been shown to reduce auditory hypersensitivity [9,10, 12,24].”
BackgroundMethodInfluentialBaguley, D. M. (2003) · Journal of the Royal Society of Medicine · doi:10.1177/014107680309601203 · Cited by 173
Wang, J., Ding, D., & Salvi, R. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00360-x · Cited by 158 · cited 1×
“This is consistent with the decrease in central inhibition [21] and the increase in neural responses over a broad frequency range [17,18,22,23] induced by hearing loss.”
BackgroundFormby, C., Sherlock, L. P., & Gold, S. L. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1582860 · Cited by 150 · cited 3×
“Indeed, decreasing (with earplugs) or increasing (stimulation with broadband noise) sensory inputs induced an increase or a decrease in auditory sensitivity, respectively [13].”
BackgroundResultPathophysiology of tinnitus: a special case--hyperacusis and a proposed treatment.
Vernon, J. (1987) · PubMed · Cited by 112
Psychometric normalisation of a hyperacusisquestionnaire
Khalfa, S. (2002) · ORL-J OTO-RHINO-LARYNGOL · Cited by 106
Fundamentals of Hearing: An Introduction
Coles, R. R. A. (1978) · Occupational and Environmental Medicine · doi:10.1136/oem.35.1.82-a · Cited by 102
Rasmussen, A. N., Olsen, S. Ø., Borgkvist, B. V., & Nielsen, L. H. (1998) · Scandinavian Audiology · doi:10.1080/010503998422665 · Cited by 20 · cited 11×
“The intensity step used in the LGOB test was then obtained by dividing the difference between the ‘too loud’ level and the absolute threshold by 14.”
BackgroundMethodResultInfluential(1996) · PubMed
Research works printed but not linked: 5
- Fabijanska, 569, Epidemiology of tinnitus and hyperacusis in Poland. In: Hazell, J, editor. Proceedings of the VIth Tinnitus Seminar. Cambridge, UK; 1999., pp, -571
- Gold, 297, Shifts in dynamic range for hyperacusis patients receiving tinnitus retraining therapy (TRT). In: Hazell J, editor. Proceedings of the VIth tinnitus seminar. Cambridge, UK; 1999., pp, -301
- McKinney, 499, Changes in loudness discomfort level and sensitivity to environmental sound with habituation based therapy. In: Hazell J, editor. Proceedings of the VIth Tinnitus Seminar. Cambridge, UK; 1999., pp, -501
- Pilgramm, 64, Rychlick R, Lebisch H, Siedentop H, Goebel G, Kirchhoff D. Tinnitus in the Federal Republic of Germany: a representative epidemiological study. In: Hazell J, editor. Proceedings of the VIth Tinnitus Seminar, Cambridge, UK; 1999., pp, -67
- Wolk, 512, The effects of managing hyperacusis with maskers (noise generators). In: Hazell J, editor. Proceedings of the VIth Tinnitus Seminar, Cambridge, UK; 1999., pp, -514
Cited by
Ringing Ears: The Neuroscience of Tinnitus: Figure 1.
Roberts, L. E., Eggermont, J. J., Caspary, D. M., Shore, S. E., Melcher, J. R., & Kaltenbach, J. A. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.4028-10.2010 · Cited by 586
“In contrast, hyperacusis (abnormal intolerance of moderate to high-intensity sounds, often accompanied by hearing loss and tinnitus) can be corrected by exposure 3 h daily for 15 weeks to background sounds disproportionately weighting the frequency range of threshold elevation (Noreña and Chery-Croze, 2007).”
BackgroundAn integrative model of tinnitus based on a central gain controlling neural sensitivity
Noreña, A. J. (2011) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2010.11.003 · Cited by 452
Self-citationGu, J. W., Halpin, C. F., Nam, E.-C., Levine, R. A., & Melcher, J. R. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00226.2010 · Cited by 310
“These results provide an entrance to understanding and quantifying physiological effects of candidate treatments for tinnitus and hyperacusis, perhaps most particularly sound therapies designed to promote a reduction in central auditory gain (Davis et al. 2007; Norena and Chery-Croze 2007).”
BackgroundUnderlying Mechanisms of Tinnitus: Review and Clinical Implications
Henry, J. A., Roberts, L. E., Caspary, D. M., Theodoroff, S. M., & Salvi, R. J. (2014) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.25.1.2 · Cited by 268
“An important demonstration comes from Noreña and Chery-Croze (2007) who showed that passive exposure to a low-level, 14 Delivered by Ingenta to: American Academy of Audiology Members IP : 98.247.24.138 On: Mon, 01 Aug 2016 02:55:31 complex background sound covering the hearing loss region for a…”
InfluentialRole of attention in the generation and modulation of tinnitus
Roberts, L. E., Husain, F. T., & Eggermont, J. J. (2013) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.07.007 · Cited by 204
Metadata
- Authors
- Noreña, A. J., & Chery-Croze, S.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Noreña, Arnaud Jean
- ORCID
- Noreña, Arnaud Jean
- Venue
- NeuroReport
- Published
- 2007-08-06
- Volume
- 18
- Issue
- 12
- Pages
- 1251-1255
- ISSN
- 0959-4965 (ISSN-L)
- OpenAlex
- W2093446377
- Cited by
- 130
- References
- 22
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 11 · 2023: 3 · 2022: 8 · 2021: 11 · 2020: 7 · 2019: 6 · 2018: 9 · 2017: 6 · 2016: 4 · 2015: 10 · 2014: 6 · 2013: 8 · 2012: 9
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Neuroreport (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
- Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
- Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Noise Effects and Management
- Keywords
- hyperacusis, auditory hypersensitivity, loudness perception, central gain, auditory sensitivity, hearing loss, sensory deprivation, hearing rehabilitation
- MeSH terms
- Acoustic Stimulation, Adaptation, Physiological, Adult, Auditory Pathways, Auditory Perceptual Disorders, Auditory Threshold, Brain, Cochlea, Female, Hearing Loss, Sensorineural, Humans, Loudness Perception, Male, Middle Aged, Neuronal Plasticity, Psychoacoustics, Hyperacusis, Hearing Loss
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.