The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Selective activation of mechanosensitive ion channels using magnetic particles
Open accessAbstract
This study reports the preliminary development of a novel magnetic particle-based technique that permits the application of highly localized mechanical forces directly to specific regions of an ion-channel structure. We demonstrate that this approach can be used to directly and selectively activate a mechanosensitive ion channel of interest, namely TREK-1. It is shown that manipulation of particles targeted against the extended extracellular loop region of TREK-1 leads to changes in whole-cell currents consistent with changes in TREK-1 activity. Responses were absent when particles were coated with RGD (Arg–Gly–Asp) peptide or when magnetic fields were applied in the absence of magnetic particles. It is concluded that changes in whole-cell current are the result of direct force application to the extracellular loop region of TREK-1 and thus these results implicate this region of the channel structure in mechano-gating. It is hypothesized that the extended loop region of TREK-1 may act as a tension spring that acts to regulate sensitivity to mechanical forces, in a nature similar to that described for MscL. The development of a technique that permits the direct manipulation of mechanosensitive ion channels in real time without the need for pharmacological drugs has huge potential benefits not only for basic biological research of ion-channel gating mechanisms, but also potentially as a tool for the treatment of human diseases caused by ion-channel dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
TREK-1, a K+ channel involved in neuroprotection and general anesthesia
Heurteaux, C., Guy, N., Laigle, C., Blondeau, N., Duprat, F., Mazzuca, M., Lang‐Lazdunski, L., Widmann, C., Zanzouri, M., Romey, G., et al. (2004) · The EMBO Journal · doi:10.1038/sj.emboj.7600234 · Cited by 534
The TREK K2P channels and their role in general anaesthesia and neuroprotection
Franks, N. P., & Honoré, E. (2004) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2004.09.003 · Cited by 214
Cited by
Progress in applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Thanh, N. T. K., Jones, S. K., & Dobson, J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224001 · Cited by 1,455
Self-citationRemote control of ion channels and neurons through magnetic-field heating of nanoparticles
Huang, H., Delikanli, S., Zeng, H., Ferkey, D. M., & Pralle, A. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.125 · Cited by 762
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Remote control of cellular behaviour with magnetic nanoparticles
Dobson, J. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.39 · Cited by 528
Self-citationNext-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Metadata
- Authors
- Hughes, S., McBain, S., Dobson, J., & El Haj, A. J.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2007-12-11
- Volume
- 5
- Issue
- 25
- Pages
- 855-863
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2159588174
- Cited by
- 197
- References
- 2
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective activation of mechanosensitive ion channels using magnetic particles. https://app.cochat.ai/papers/10.1098/rsif.2007.1274
- The paper
- Hughes, S., McBain, S., Dobson, J., & El Haj, A. J. (2008). Selective activation of mechanosensitive ion channels using magnetic particles. Journal of The Royal Society Interface. https://doi.org/10.1098/rsif.2007.1274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.