Nano-Ag-loaded hydroxyapatite coatings on titanium surfaces by electrochemical deposition
Open accessThe DOI matches its Crossref record.
Abstract
Hydroxyapatite (HA) coatings on titanium (Ti) substrates have attracted much attention owing to the combination of good mechanical properties of Ti and superior biocompatibility of HA. Incorporating silver (Ag) into HA coatings is an effective method to impart the coatings with antibacterial properties. However, the uniform distribution of Ag is still a challenge and Ag particles in the coatings are easy to agglomerate, which in turn affects the applications of the coatings. In this study, we employed pulsed electrochemical deposition to co-deposit HA and Ag simultaneously, which realized the uniform distribution of Ag particles in the coatings. This method was based on the use of a well-designed electrolyte containing Ag ions, calcium ions and l -cysteine, in which cysteine acted as the coordination agent to stabilize Ag ions. The antibacterial and cell culture tests were used to evaluate the antibacterial properties and biocompatibility of HA/Ag composite coatings, respectively. The results indicated the as-prepared coatings had good antibacterial properties and biocompatibility. However, an appropriate silver content should be chosen to balance the biocompatibility and antibacterial properties. Heat treatments promoted the adhesive strength and enhanced the biocompatibility without sacrificing the antibacterial properties of the HA/Ag coatings. In summary, this study provided an alternative method to prepare bioactive surfaces with bactericidal ability for biomedical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sardi, J. C. O., Scorzoni, L., Bernardi, T., Fusco-Almeida, A. M., & Mendes Giannini, M. J. S. (2013) · Journal of Medical Microbiology · doi:10.1099/jmm.0.045054-0 · Cited by 1,184
Biomimetic porous scaffolds for bone tissue engineering
Wu, S., Liu, X., Yeung, K. W. K., Liu, C., & Yang, X. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.04.001 · Cited by 1,159
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Review of titanium surface modification techniques and coatings for antibacterial applications
Chouirfa, H., Bouloussa, H., Migonney, V., & Falentin-Daudré, C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.10.036 · Cited by 1,031
Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – A review
Surmenev, R. A., Surmeneva, M. A., & Ivanova, A. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.036 · Cited by 712
Xie, C.-M., Lu, X., Wang, K.-F., Meng, F.-Z., Jiang, O., Zhang, H.-P., Zhi, W., & Fang, L.-M. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501428e · Cited by 207
Self-citationHe, S., Zhou, P., Wang, L., Xiong, X., Zhang, Y., Deng, Y., & Wei, S. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0169 · Cited by 142
“Titanium and titanium-based alloys with excellent properties (load-bearing, low density and biocompatibility) have been widely used as artificial implants in dental, bone replacement and orthopaedic surgery [3].”
BackgroundXie, C., Lu, X., Wang, K., Yuan, H., Fang, L., Zheng, X., Chan, C., Ren, F., & Zhao, C. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00015 · Cited by 62
Self-citation
Metadata
- Authors
- Lu, X., Zhang, B., Wang, Y., Zhou, X., Weng, J., Qu, S., Feng, B., Watari, F., Ding, Y., & Leng, Y.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2010-09-29
- Volume
- 8
- Issue
- 57
- Pages
- 529-539
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2150302064
- Cited by
- 90
- References
- 0
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.