Artificial fish skin of self-powered micro-electromechanical systems hair cells for sensing hydrodynamic flow phenomena
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Using biological sensors, aquatic animals like fishes are capable of performing impressive behaviours such as super-manoeuvrability, hydrodynamic flow ‘vision’ and object localization with a success unmatched by human-engineered technologies. Inspired by the multiple functionalities of the ubiquitous lateral-line sensors of fishes, we developed flexible and surface-mountable arrays of micro-electromechanical systems (MEMS) artificial hair cell flow sensors. This paper reports the development of the MEMS artificial versions of superficial and canal neuromasts and experimental characterization of their unique flow-sensing roles. Our MEMS flow sensors feature a stereolithographically fabricated polymer hair cell mounted on Pb(Zr 0.52 Ti 0.48)O 3 micro-diaphragm with floating bottom electrode. Canal-inspired versions are developed by mounting a polymer canal with pores that guide external flows to the hair cells embedded in the canal. Experimental results conducted employing our MEMS artificial superficial neuromasts (SNs) demonstrated a high sensitivity and very low threshold detection limit of 22 mV/(mm s−1) and 8.2 µm s−1, respectively, for an oscillating dipole stimulus vibrating at 35 Hz. Flexible arrays of such superficial sensors were demonstrated to localize an underwater dipole stimulus. Comparative experimental studies revealed a high-pass filtering nature of the canal encapsulated sensors with a cut-off frequency of 10 Hz and a flat frequency response of artificial SNs. Flexible arrays of self-powered, miniaturized, light-weight, low-cost and robust artificial lateral-line systems could enhance the capabilities of underwater vehicles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jaalouk, D. E., & Lammerding, J. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2597 · Cited by 1,396 · cited 4×
“The hair cells form the fundamental sensing elements, which act as mechano-electrical transducers by converting the flow induced mechanical bending into electrical potentials that are sent through the innervated afferent fibres to the brain of the fish [1].”
BackgroundInfluential
Cited by
Materials, Actuators, and Sensors for Soft Bioinspired Robots
Ilami, M., Bagheri, H., Ahmed, R., Skowronek, E. O., & Marvi, H. (2021) · Advanced Materials · doi:10.1002/adma.202003139 · Cited by 435
Cao, X., Xiong, Y., Sun, J., Zhu, X., Sun, Q., & Wang, Z. L. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202102983 · Cited by 360
Biosensors Based on Mechanical and Electrical Detection Techniques
Chalklen, T., Jing, Q., & Kar-Narayan, S. (2020) · Sensors · doi:10.3390/s20195605 · Cited by 133
Metadata
- Authors
- Asadnia, M., Kottapalli, A. G. P., Miao, J., Warkiani, M. E., & Triantafyllou, M. S.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2015-10
- Volume
- 12
- Issue
- 111
- Pages
- 20150322
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2309430239
- Cited by
- 151
- References
- 1
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial fish skin of self-powered micro-electromechanical systems hair cells for sensing hydrodynamic flow phenomena. https://app.cochat.ai/papers/10.1098/rsif.2015.0322
- The paper
- Asadnia, M., Kottapalli, A. G. P., Miao, J., Warkiani, M. E., & Triantafyllou, M. S. (2015). Artificial fish skin of self-powered micro-electromechanical systems hair cells for sensing hydrodynamic flow phenomena. Journal of The Royal Society Interface. https://doi.org/10.1098/rsif.2015.0322
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.