The DOI matches its Crossref record.
The reflection of X-rays by crystals
Open accessAbstract
In a discussion of the Laue photographs it has been shown that they may conveniently be interpreted as due to the reflection of X-rays in such planes within the crystal as are rich in atoms. This leads at once to the attempt to use cleavage planes as mirrors, and it has been found that mica gives a reflected pencil from its cleavage plane strong enough to make a visible impression on a photographic plate in a few minutes’ exposure. It has also been observed that the reflected pencil can be detected by the ionisation method. For the purpose of examining more closely the reflection of X-rays in this manner we have used an apparatus resembling a spectrometer in form, an ionisation chamber taking the place of the telescope. The collimator is replaced by a lead block pierced by a hole which can be stopped down to slits of various widths. The revolving table in the centre carries the crystal. The ionisation chamber is tubular, 15 cm. long and 5 cm. in diameter. It can be rotated about the axis of the instrument, to which its own axis is perpendicular. It is filled with sulphur dioxide in order to increase the ionisation current: both air and methyl iodide have also been used occasionally to make sure that no special characteristics of the gas in the chamber affect the interpretation of the results. The ionisation current is measured directly. A balance method has not been used as we have not found it possible to deflect a suitable portion of the primary rays into a balance chamber.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effect of interlayer anions on [NiFe]-LDH nanosheet water oxidation activity
Hunter, B. M., Hieringer, W., Winkler, J. R., Gray, H. B., & Müller, A. M. (2016) · Energy & Environmental Science · doi:10.1039/c6ee00377j · Cited by 616
Pitfalls in the characterization of nanoporous and nanosized materials
Weidenthaler, C. (2011) · Nanoscale · doi:10.1039/c0nr00561d · Cited by 256
Li, M.-J., Liu, C.-M., Xie, Y.-B., Cao, H.-B., Zhao, H., & Zhang, Y. (2014) · Carbon · doi:10.1016/j.carbon.2013.09.004 · Cited by 202
Tomoda, B. T., Yassue-Cordeiro, P. H., Ernesto, J. V., Lopes, P. S., Péres, L. O., da Silva, C. F., & de Moraes, M. A. (2020) · Biopolymer Membranes and Films · doi:10.1016/b978-0-12-818134-8.00003-1 · Cited by 63
III-N/Si₃N₄ Integrated Photonics Platform for Blue Wavelengths
Arefin, R., Ramachandra, S. H., Jung, H., You, W., Hasan, S. M. N., Turski, H., Dwivedi, S., & Arafin, S. (2020) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.2020.2993634 · Cited by 19
Metadata
- Authors
- Bragg, W. H., & Bragg, W. L.
- Venue
- Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character
- Publisher
- The Royal Society
- Published
- 1913-07-01
- Volume
- 88
- Issue
- 605
- Pages
- 428-438
- ISSN
- 0950-1207 (ISSN-L)
- 2053-9150
- OpenAlex
- W1986715836
- Cited by
- 1,462
- References
- 0
- FWCI
- 24.05
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The reflection of X-rays by crystals. https://app.cochat.ai/papers/10.1098/rspa.1913.0040
- The paper
- Bragg, W. H., & Bragg, W. L. (1913). The reflection of X-rays by crystals. Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character. https://doi.org/10.1098/rspa.1913.0040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.