The DOI matches its Crossref record.
Fluid motion in a curved channel
Open accessAbstract
Experimental work due to Prof. J. Eustice has shown that there is no marked critical velocity for a fluid flowing through a curved pipe. If the pipe is straight there is a sudden increase in the loss of head as soon as the velocity exceeds its critical value; below the critical the loss of head varies as the first power of the velocity, but above it approximately as the second power. But if the pipe is curved there does not appear to be such a sudden change at any velocity of flow. One possibility is that flow through a curved pipe is stream-line at velocities much greater than the critical for a straight pipe, but experiment seems to show that the critical velocity is smaller in a curved pipe than in a straight one. If then the motion in a curved pipe becomes unstable at a velocity somewhat less than the critical for a straight pipe, the absence of a sudden increase in the loss of head in this region suggests that the stream-line motion in a curved pipe (unlike that in a straight pipe) is unstable for small disturbances. A similar problem shows that it is not unlikely that curvature may have such an effect: it is believed that uniform shearing motion between flat plates is stable for small disturbances, but Prof. G. I. Taylor has shown that shearing motion between concentric cylinders can in certain conditions become unstable for small disturbances. A theoretical investigation of the stability of flow in a curved pipe is certain to be a matter of great difficulty, and therefore a simplified form of the problem, the stability of flow under pressure through a curved channel (i. e., between concentric cylinders), is here considered. It is shown that the motion can become unstable for a small disturbance of exactly the type found by Taylor to be possible in motion between rotating cylinders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Inertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics
Warkiani, M. E., Khoo, B. L., Wu, L., Tay, A. K. P., Bhagat, A. A. S., Han, J., & Lim, C. T. (2016) · Nature Protocols · doi:10.1038/nprot.2016.003 · Cited by 548
Hydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
Metadata
- Authors
- Dean, W. R.
- Venue
- Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character
- Publisher
- The Royal Society
- Published
- 1928-11-01
- Volume
- 121
- Issue
- 787
- Pages
- 402-420
- ISSN
- 0950-1207 (ISSN-L)
- 2053-9150
- OpenAlex
- W2006156467
- Cited by
- 541
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluid motion in a curved channel. https://app.cochat.ai/papers/10.1098/rspa.1928.0205
- The paper
- Dean, W. R. (1928). Fluid motion in a curved channel. Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character. https://doi.org/10.1098/rspa.1928.0205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.