The DOI matches its Crossref record.
Pulsed endor experiments
Abstract
A new technique for performing electron nuclear double resonance experiments, based on the observation of electron spin echoes, has been developed. Radio-frequency resonance transitions are induced during the time interval between pulses II and III of a stimulated echo sequence, and cause a fall in the echo signal amplitude. Echo signals are integrated by means of a boxcar circuit and made to operate a pen recorder which plots the endor spectrum as the radio frequency is varied. The method does not depend on achieving any particular balance between relaxation rates, and has been applied in studying the Ce-W system in (Ca, Ce) WO4 down to very low radio frequencies. Three microwave pulses are required in order to generate a stimulated electron echo (figure 17 (a)). According to the classical description, in terms of a co-ordinate system rotating at the microwave frequency, the first pulse, which is a 90° pulse, turns the spins into the equatorial plane where they precess freely for a time ז, some advancing and some lagging the microwave field in phase. The second pulse, like the first a 90° pulse, has an effect which varies according to the phase divergence of the spins. Those which precess exactly at the microwave frequency, or which have diverged by a multiple of 2π, are turned along the polar axis in a direction opposite to that of their original alinement; the two 90° pulses are, for these spins, equivalent to a single 180° pulse. Spins which have diverged by an odd multiple of π are turned back into their original alinement as if no pulses had been applied. Other spins are turned by varying amounts, the overall effects being to leave a sinusoidal spectral pattern of periodicity 2π/ז in place of the original smooth line shape (figure 17 (b)). This pattern will persist for a relatively long time T, limited by lattice relaxation, or by spectral diffusion, but not by the phase memory time observed in normal spin echoes. The third microwave pulse of the stimulated echo sequence, also a 90° pulse, turns the Mz pattern into the equatorial plane where a phase convergence takes place, leading to the emission of a stimulated echo signal a time ז later. If this simple picture is to be applicable, the microwave field strength H1 should be several times greater than the resonance line width. Such large fields, and the corresponding short pulse times, are not always convenient in electron echo experiments, nor are they usually necessary. Echoes can be obtained with lower fields, although the behaviour of the spins becomes more complicated (Bloom 1955). In practice one can visualize the situation sufficiently well by imagining a spectrum of spins ~ 2H1 wide to be selected and to constitute the effective resonance line.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
[NiFe] and [FeFe] Hydrogenases Studied by Advanced Magnetic Resonance Techniques
Lubitz, W., Reijerse, E., & van Gastel, M. (2007) · Chemical Reviews · doi:10.1021/cr050186q · Cited by 482
Tabares, L. C., & Un, S. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.c112.444992 · Cited by 47
Gagnon, D. M., Stich, T. A., Mehta, A. P., Abdelwahed, S. H., Begley, T. P., & Britt, R. D. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b05686 · Cited by 21
Metadata
- Authors
- Mims, W. B.
- Venue
- Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences
- Publisher
- The Royal Society
- Published
- 1965-01-26
- Volume
- 283
- Issue
- 1395
- Pages
- 452-457
- ISSN
- 0080-4630 (ISSN-L)
- 2053-9169
- OpenAlex
- W2005574154
- Cited by
- 316
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulsed endor experiments. https://app.cochat.ai/papers/10.1098/rspa.1965.0034
- The paper
- Mims, W. B. (1965). Pulsed endor experiments. Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences. https://doi.org/10.1098/rspa.1965.0034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.