The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
The reconstruction of a three-dimensional structure from projections and its application to electron microscopy
Abstract
A transmission electron micrograph is essentially a projection of the specimen in the direction of view. In order to reconstruct a three-dimensional image of the specimen, it is necessary to be able to combine data from a number of different views. A formal solution of this problem is given in terms of Fourier transforms. Its realization requires data reduction and interpolation. The final solution is given by a least squares approach, which also indicates how many views must be included to give a valid reconstruction of a given particle to a given degree of resolution. Interpolation procedures of varying power are given, to be employed according to the economy with which the available data must be used. An alternative procedure is described for direct reconstruction without the use of Fourier transforms, but it is shown to be in general less practicable than the Fourier approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Maramorosch, K., & Koprowski, H. (1984) · Medical Entomology and Zoology · Cited by 985
The detection of sub-units within the crystallographic asymmetric unit
Rossmann, M. G., & Blow, D. M. (1962) · Acta Crystallographica · doi:10.1107/s0365110x62000067 · Cited by 868
Some implications of a theorem due to Shannon
Sayre, D. (1952) · Acta Crystallographica · doi:10.1107/s0365110x52002276 · Cited by 557
Diffraction by helical structures
Klug, A., Crick, F. H. C., & Wyckoff, H. W. (1958) · Acta Crystallographica · doi:10.1107/s0365110x58000517 · Cited by 430
Self-citationCROWTHER, R. A., AMOS, L. A., FINCH, J. T., DE ROSIER, D. J., & KLUG, A. (1970) · Nature · doi:10.1038/226421a0 · Cited by 346
Self-citationA computer-linked cathode-ray tube microdensitometer for X-ray crystallography
Arndt, U. W., Crowther, R. A., & Mallett, J. F. W. (1968) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/1/5/303 · Cited by 78
Self-citation
Cited by
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
Andersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Dual-Axis Tomography: An Approach with Alignment Methods That Preserve Resolution
Mastronarde, D. N. (1997) · Journal of Structural Biology · doi:10.1006/jsbi.1997.3919 · Cited by 1,057
3D electron microscopy in the physical sciences: the development of Z-contrast and EFTEM tomography
Midgley, P. A., & Weyland, M. (2003) · Ultramicroscopy · doi:10.1016/s0304-3991(03)00105-0 · Cited by 1,028
Metadata
- Authors
- Crowther, R. A., DeRosier, D. J., & Klug, A.
- Venue
- Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences
- Publisher
- The Royal Society
- Published
- 1970-06-23
- Volume
- 317
- Issue
- 1530
- Pages
- 319-340
- ISSN
- 0080-4630 (ISSN-L)
- 2053-9169
- OpenAlex
- W2127581985
- Cited by
- 972
- References
- 7
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.