The DOI matches its Crossref record.
The relationship between the mode of operation and the dimensions of the junctional regions at synapses and motor end-organs
Abstract
An attempt has been made to correlate the dimensions of synapses as revealed by electron-microscopy with their functional operation. In particular the problems under consideration have concerned the synaptic cleft, which is the narrow space, 200 to 500 Å across, that separates the pre-synaptic from the sub-synaptic membrane. The synaptic transmitter substance is liberated from the pre-synaptic membrane into this space. By making simplifying assumptions it has been possible to derive equations relating to the elimination of transmitter substance from this space by diffusion into the surrounding medium. These equations apply to two types of synaptic contact, the long strip-like and the circular knob-like. It is shown that with some synapses the time course of this elimination is satisfactorily described by these equations for both geometrical types of synapses. For both geometrical types of synapses equations have also been derived that enable their efficiencies to be assessed in respect of the flow of electric current through the synaptic cleft and so to the whole membrane of the post-synaptic structure. Essentially synapses are devices for causing the flow of these currents, and they appear to be very efficiently designed for this purpose. Despite their narrowness the synaptic clefts probably offer a negligible resistance to the flow of these post-synaptic currents. There is a general discussion on the efficiency of design of synaptic structures of diverse types.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jonas, P., Major, G., & Sakmann, B. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019965 · Cited by 720
A quantitative description of end‐plate currents
Magleby, K. L., & Stevens, C. F. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009840 · Cited by 616
Dendritic location of synapses and possible mechanisms for the monosynaptic EPSP in motoneurons.
Rall, W., Burke, R. E., Smith, T. G., Nelson, P. G., & Frank, K. (1967) · Journal of Neurophysiology · doi:10.1152/jn.1967.30.5.1169 · Cited by 606
Transmitter timecourse in the synaptic cleft: its role in central synaptic function
Clements, J. D. (1996) · Trends in Neurosciences · doi:10.1016/s0166-2236(96)10024-2 · Cited by 598
Synaptic Activation of Glutamate Transporters in Hippocampal Astrocytes
Bergles, D. E., & Jahr, C. E. (1997) · Neuron · doi:10.1016/s0896-6273(00)80420-1 · Cited by 516
Metadata
- Authors
- Eccles, J. C., & Jaeger, J. C.
- Venue
- Proceedings of the Royal Society of London. Series B - Biological Sciences
- Publisher
- The Royal Society
- Published
- 1958-01-01
- Volume
- 148
- Issue
- 930
- Pages
- 38-56
- ISSN
- 0080-4649 (ISSN-L)
- 2053-9193
- OpenAlex
- W2018662775
- Cited by
- 236
- References
- 0
- FWCI
- 6.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The relationship between the mode of operation and the dimensions of the junctional regions at synapses and motor end-organs. https://app.cochat.ai/papers/10.1098/rspb.1958.0003
- The paper
- Eccles, J. C., & Jaeger, J. C. (1958). The relationship between the mode of operation and the dimensions of the junctional regions at synapses and motor end-organs. Proceedings of the Royal Society of London. Series B - Biological Sciences. https://doi.org/10.1098/rspb.1958.0003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.