CoChat

Physiology of H I horizontal cells in the primate retina

Dacheux, R. F., Raviola, E. · 1990 · Proceedings of the Royal Society of London. B. Biological Sciences
Cited by 51

The DOI matches its Crossref record.

Abstract

Two types of recording were obtained from horizontal cells in the superfused eyecup preparation of the retina of Macaca mulatta. Injection of horseradish peroxidase showed that one class of responses was generated by the cell body of H I horizontal cells. The origin of the other type of responses was not identified morphologically, but they were strikingly similar to those recorded from the axonal arborization of axon-bearing horizontal cells of other mammalian species. The soma of H I cells responded with graded hyperpolarizations to increasing changes in diffuse white-light illumination. Threshold responses were obtained with stimulus intensities above electroretinogram (ERG) b-wave threshold; this was taken as an indication of cone input to this part of the cell. Responses to low-intensity stimuli were small, sustained hyperpolarizations; at intermediate intensities, the hyperpolarizations were initiated by a prominent transient component and were followed by a small rod after-effect at stimulus termination; with bright flashes, the transient component was abolished and the rod after-effect became larger. The spectral input of the H I cell body was tested with chromatic stimuli matching the spectral sensitivity of primate cone pigments: responses to all wavelengths were hyperpolarizations. Spectral sensitivity values for the different wavelengths and a comparison of the spectral amplitude–intensity curves for 450 nm, 540 nm and 630 nm wavelengths suggested that H I cell bodies had a non-specific, broad-band sensitivity to mid-spectral wavelengths. Thus more than one spectrally sensitive mechanism was involved in the generation of their response and they were not univariant. This was supported by the morphological observation that the clusters of terminal dendritic branchlets of H I cells had the same arrangement and distance from each other as the overlying cone inner segments, suggesting that these cells contact cones in an indiscriminate fashion. The other class of horizontal cell responses were characterized by a lower threshold, a larger amplitude with low intensity stimuli, a steeper increment in amplitude with increasing intensity, a saturation at moderate levels of illumination and a prominent rod after-effect in response to bright-light stimuli. We concluded that these responses were generated by the axon terminal of H I horizontal cells, that receives synaptic input from rods. Thus H I horizontal cells belong to the luminosity type, are not involved in the processing of colour contrast and are homologous to the axon-bearing horizontal cells of other mammalian retinas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rspb.1990.0014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Dacheux, R. F., & Raviola, E.
Venue
Proceedings of the Royal Society of London. B. Biological Sciences
Published
1990-03-22
Volume
239
Issue
1295
Pages
213-230
ISSN
  • 0080-4649 (ISSN-L)
  • 2053-9193
OpenAlex
W2142774646
Cited by
51
References
0
FWCI
0.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.